
TCL Solar · TCL-G12-725-66P
TCL Solar TOPCon Bifacial 725 W ModuleA large-format bifacial module for arrays where structure, handling and string-current limits are designed around the exact reference.
Store · Assisted equipment selection
Compare equipment by system role, application and budget. ReneWave confirms compatibility, availability, delivery and price in writing.
Product finder
All equipment
176 matching products
View matching productsTCL Solar · TCL-G12-725-66P
TCL Solar TOPCon Bifacial 725 W ModuleA large-format bifacial module for arrays where structure, handling and string-current limits are designed around the exact reference.
TCL Solar · TCL-G12-620-66P
TCL Solar TOPCon Bifacial 620 W ModuleA narrower-format bifacial module for roofs where usable layout, handling and string-current limits drive the exact reference.
Canadian Solar · CS7N-705TB-AG
Canadian Solar TOPBiHiKu7 705 W N-Type TOPCon Bifacial ModuleA large-format 705 W bifacial module for arrays whose structure, access and electrical design support the exact reference.
Canadian Solar · CS7N-710TB-AG
Canadian Solar TOPBiHiKu7 Bifacial 710 W ModuleA large-format 710 W bifacial module for arrays whose structure, access and electrical design support the exact reference.
Canadian Solar · CS7N-715TB-AG
Canadian Solar TOPBiHiKu7 Bifacial 715 W ModuleA large-format 715 W bifacial module for arrays whose structure, access and electrical design support the exact reference.
Canadian Solar · CS7N-720TB-AG
Canadian Solar TOPBiHiKu7 Bifacial 720 W ModuleA large-format 720 W bifacial module for arrays whose structure, access and electrical design support the exact reference.
JinkoSolar · JKM590N-72HL4-BDV
JinkoSolar Tiger Neo Bifacial 590 W ModuleA 590 W bifacial module for commercial arrays where roof coverage, current limits and handling favor its format.
JinkoSolar · JKM620N-66HL4M-BDV
JinkoSolar Tiger Neo Bifacial 620 W ModuleA 620 W bifacial module assessed against the complete array, structure and conversion design rather than a five-watt difference.
JinkoSolar · JKM625N-66HL4M-BDV
JinkoSolar Tiger Neo Bifacial 625 W ModuleA high-output bifacial module for arrays whose structure, handling and electrical design support its format and current.
JinkoSolar · JKM720N-66HL5-BDV
JinkoSolar Tiger Neo Bifacial 720 W ModuleA large-format 720 W bifacial module for arrays designed around its width, handling weight and higher string current.
Huawei FusionSolar · SUN2000-3KTL-L1
Huawei SUN2000 3 kW Single-Phase Solar InverterA compact two-MPPT solar inverter for single-phase systems, with optional Huawei storage and backup equipment confirmed separately.
Deye · SUN-5K-SG05LP1-EU
Deye SUN 5 kW Single-Phase Low-Voltage Hybrid InverterA 5 kW low-voltage hybrid inverter coordinating two PV trackers, 48 V storage, grid or generator charging and a protected load output.
Deye · SUN-10K-SG02LP1-EU-AM3
Deye SUN 10 kW Single-Phase Low-Voltage Hybrid InverterA 10 kW low-voltage hybrid inverter coordinating three PV trackers, a high-current 48 V storage interface and a protected load output.
MUST · PV19-10048-EXP
MUST PV1900 EXP 10 kW Single-Phase Off-Grid Solar Inverter/ChargerA dual-MPPT off-grid inverter/charger for a reviewed 48 V battery system and one exclusively selected utility or generator AC source.
MUST · PV18-6248-PREM
MUST PV18-6248 PREM 6.2 kW 48 V Off-Grid Inverter/ChargerMode-dependent off-grid conversion: 6.2 kW with PV input above 1,000 W, 5.5 kW in battery mode.
MUST · PV18-4024-PREM
MUST PV18-4024 PREM 4 kW 24 V Off-Grid Inverter/ChargerMode-dependent off-grid conversion: 4 kW with PV input above 1,000 W, 3.5 kW in battery mode.
MUST · PV18-3524-PREM
MUST PV18-3524 PREM 3.5 kW 24 V Off-Grid Inverter/ChargerSingle-phase off-grid conversion and controlled charging for a reviewed 24 V battery architecture.
MUST · PV30-6048-VHM
MUST PV30-6048 VHM 6 kW 48 V Off-Grid Inverter/ChargerSingle-phase off-grid conversion and controlled charging for a reviewed 48 V battery architecture.
Deye · SUN-10K-SG05LP3-EU-SM2
Deye SUN 10 kW Three-Phase Low-Voltage Hybrid InverterA three-phase hybrid inverter coordinating two PV trackers, a high-current 48 V battery interface, utility, generator and selected-load backup paths.
Deye · SUN-20K-SG05LP3-EU-SM2
Deye SUN 20 kW Three-Phase Low-Voltage Hybrid InverterA higher-output three-phase hybrid inverter coordinating two PV trackers, two 48 V battery inputs, utility, generator and selected-load backup paths.
Deye · SUN-12K-SG04LP3-EU
Deye SUN 12 kW Three-Phase Low-Voltage Hybrid InverterA 12 kW three-phase hybrid inverter coordinating two PV trackers, a high-current 48 V battery interface and selected-load backup paths.
Deye · SUN-20K-SG01HP3-EU-AM2
Deye SUN 20 kW Three-Phase High-Voltage Hybrid InverterA three-phase hybrid inverter coordinating two PV trackers, one high-voltage lithium storage interface, utility, generator and selected-load backup paths.
Deye · SUN-30K-SG02HP3-EU-AM3
Deye SUN 30 kW Three-Phase High-Voltage Hybrid InverterA 30 kW three-phase hybrid inverter coordinating three PV trackers, high-voltage lithium storage, utility, generator and selected-load backup paths.
Deye · SUN-50K-SG01HP3-EU-BM4
Deye SUN 50 kW Three-Phase High-Voltage Hybrid InverterA 50 kW three-phase hybrid inverter coordinating four PV trackers, two high-voltage lithium battery inputs, utility, generator and selected-load backup paths.
Deye · SUN-80K-SG02HP3-EU-EM6
Deye SUN 80 kW Three-Phase High-Voltage Hybrid InverterAn 80 kW three-phase hybrid inverter coordinating six PV trackers, two high-voltage lithium battery inputs, utility, generator and selected-load backup paths.
Huawei FusionSolar · SUN2000-5KTL-M1-EU
Huawei SUN2000 5 kW Three-Phase Solar InverterA two-MPPT three-phase solar inverter with a separately validated Huawei storage and selected-load backup path.
Huawei FusionSolar · SUN2000-5K-MAP0
Huawei SUN2000 5 kW Three-Phase Hybrid Solar InverterA three-phase hybrid inverter with two MPPTs and separately validated Huawei storage and SmartGuard backup paths.
Huawei FusionSolar · SUN2000-8K-MAP0
Huawei SUN2000 8 kW Three-Phase Hybrid Solar InverterA three-phase hybrid inverter with two MPPTs and separately validated Huawei storage and SmartGuard backup paths.
Huawei FusionSolar · SUN2000-10K-MAP0
Huawei SUN2000 10 kW Three-Phase Hybrid Solar InverterA three-phase hybrid inverter with two MPPTs and separately validated Huawei storage and SmartGuard backup paths.
Huawei FusionSolar · SUN2000-15K-MB0
Huawei SUN2000 15 kW Three-Phase Hybrid Solar InverterA higher-capacity three-phase hybrid inverter with four designed PV inputs, two storage terminals and separately engineered SmartGuard backup.
Huawei FusionSolar · SUN2000-20K-MB0
Huawei SUN2000 20 kW Three-Phase Hybrid Solar InverterA 20 kW three-phase hybrid inverter with four designed PV inputs, two storage terminals and a separately engineered SmartGuard path for selected single-phase backup loads.
Huawei FusionSolar · SUN2000-30KTL-M3
Huawei SUN2000 30 kW Three-Phase String InverterA four-MPPT commercial string inverter for calculated three-phase PV arrays, with no battery or backup function.
Huawei FusionSolar · SUN2000-40KTL-M3
Huawei SUN2000 40 kW Three-Phase String InverterA four-MPPT commercial string inverter for calculated 40 kW three-phase PV arrays, with no battery or backup function.
Huawei FusionSolar · SUN2000-50KTL-M3
Huawei SUN2000 50 kW Three-Phase String InverterA four-MPPT commercial string inverter for calculated 50 kW three-phase PV arrays, with no battery or backup function.
Huawei FusionSolar · SUN2000-100KTL-M2
Huawei SUN2000 100 kW Three-Phase String InverterA 10-MPPT commercial string inverter for calculated 100 kW three-phase PV plants, with no battery or backup function.
Huawei FusionSolar · SUN2000-115KTL-M2
Huawei SUN2000 115 kW Three-Phase String InverterA 10-MPPT commercial string inverter for calculated 115 kW three-phase PV plants, with no battery or backup function.
Huawei FusionSolar · SUN2000-150K-MG0
Huawei SUN2000 150 kW Three-Phase String InverterA 7-MPPT commercial string inverter for calculated 150 kW three-phase PV plants, with no battery or backup function.
Huawei FusionSolar · LUNA2000-5-E1
Huawei LUNA2000 S1 5 kWh Battery ModuleA 5 kWh LiFePO4 module for Huawei LUNA2000-S1 storage. It requires the separate C1 power module and a compatible Huawei inverter.
Huawei FusionSolar · LUNA2000-5-E0
Huawei LUNA2000 5 kWh Battery ModuleA cell-containing 5 kWh S0 battery module used behind the separately ordered LUNA2000-5KW-C0 controller.
Dyness · S51100
Dyness S51100 STACK100 5.12 kWh High-Voltage Battery ModuleA cell-containing 5.12 kWh LiFePO4 module for a controlled Dyness STACK100 high-voltage cluster.
Dyness · DL5.0C
Dyness DL5.0C 5.12 kWh Low-Voltage BatteryA 51.2 V LiFePO4 battery with integrated BMS for a separately validated low-voltage inverter/charger architecture.
Dyness · POWERBOX-PRO
Dyness PowerBox Pro 10.24 kWh Low-Voltage BatteryA weather-protected 51.2 V LiFePO4 battery with integrated BMS for a separately validated low-voltage inverter/charger architecture.
OUTDO · OT100-12GEL
OUTDO OT100 12 V 100 Ah GEL Deep-Cycle BatteryRate-defined 12 V GEL storage for an engineered battery bank and compatible inverter/charger.
OUTDO · OT150-12GEL
OUTDO OT150 12 V 150 Ah GEL Deep-Cycle BatteryA rate-defined sealed GEL battery for a deliberately designed DC bank and compatible inverter/charger.
OUTDO · OT200-12GEL
OUTDO OT200 12 V 200 Ah GEL Deep-Cycle BatteryA rate-defined sealed GEL battery for a deliberately designed DC bank and compatible inverter/charger.
OUTDO · OT270-12GEL
OUTDO OT270 12 V 270 Ah GEL Deep-Cycle BatteryA high-capacity sealed GEL battery for a deliberately designed DC bank and compatible inverter/charger.
VEICHI · VEICHI-4VSA
VEICHI 4VSA 4-inch Submersible Borehole PumpA complete AC pump and motor assembly selected for the flow and total dynamic head of your borehole.
VEICHI · VEICHI-4VSP
VEICHI 4VSP 4-inch Submersible Borehole PumpA complete AC pump and motor assembly selected for the flow and total dynamic head of your borehole.
VEICHI · VEICHI-6VSP
VEICHI 6VSP 6-inch Submersible Borehole PumpA complete AC pump and motor assembly selected for the flow and total dynamic head of your borehole.
Huawei FusionSolar · LUNA2000-10KW-C1
Huawei LUNA2000 S1 Battery Power ModuleThe C1 controls a Huawei S1 stack of one to three E1 battery modules. Battery modules and the compatible inverter are ordered separately.
Huawei FusionSolar · LUNA2000-5KW-C0
Huawei LUNA2000 5 kW Battery Power ModuleThe power-control layer for a modular Huawei LUNA2000-S0 stack; it contains no battery cells or usable energy capacity.
Dyness · SBDU100
Dyness SBDU100 STACK100 High-Voltage Battery Controller & Floor BaseThe protection, communication and high-voltage connection layer for a Dyness STACK100 cluster; no battery cells or energy capacity are included.
Huawei FusionSolar · SD-WLAN
Huawei Smart Dongle WLAN/EthernetWLAN or Ethernet through a router for a compatible Huawei inverter monitoring architecture.
Huawei FusionSolar · SD-4G
Huawei Smart Dongle 4GCellular monitoring through a mobile network for a compatible Huawei inverter monitoring architecture.
Huawei FusionSolar · SMARTLOGGER3000A
Huawei SmartLogger3000A PV Plant Communications ControllerPlant-level communications, commissioning and control coordination for reviewed Huawei PV architectures.
CHINT · DTSU666-H-100A
CHINT DTSU666-H 100 A Three-Phase Smart Power SensorThree-phase current, voltage, power and energy measurement for compatible Huawei control architectures.
Huawei FusionSolar · SMARTGUARD-63A-T0
Huawei SmartGuard 63 A Three-Phase Backup & Energy ControllerSwitching, measurement and energy control for compatible Huawei backup architectures; it performs no power conversion.
ABB · M202-32A
ABB M202-32A 2P magnetic-only breakerShort circuits, subject to the verified installation and breaking-capacity rating.
ABB · IN FH202 40A-30mA/AC
ABB IN FH202 40 A / 30 mA Type AC RCCBResidual-current faults of the Type AC waveform at a rated sensitivity of 30 mA.
ABB · S202L-C63
ABB S202L-C63 2P C-curve breakerOverload and short circuits when the circuit design and rated breaking capacity are suitable.
ABB · SH203-C16
ABB SH203-C16 · thermal-magnetic 3P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S203-C25
ABB S203-C25 · thermal-magnetic 3P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · M203-32A
ABB M203-32A · magnetic-only 3P breakerNo overload protection in this device. A separate coordinated overload device is required; this is not a complete motor-protection assembly.
ABB · S203-D50
ABB S203-D50 · thermal-magnetic 3P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S203-C80
ABB S203-C80 · thermal-magnetic 3P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S803P-C80
ABB S803P-C80 · thermal-magnetic 3P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S803P-C100
ABB S803P-C100 · thermal-magnetic 3P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S803N-C125
ABB S803N-C125 · thermal-magnetic 3P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · 1SDA067057R1
ABB XT2N 160 Ekip LS/I · 100 A · 3PL protects against overload; short-circuit protection is selected as delayed S or instantaneous I, not both simultaneously. No G function is claimed.
ABB · 1SDA067062R1
ABB XT2N 160 Ekip I · 100 A · 3PNo overload protection in this device. A separate coordinated overload device is required; this is not a complete motor-protection assembly.
ABB · S204L-C16
ABB S204L-C16 · thermal-magnetic 4P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S204-C20
ABB S204-C20 · thermal-magnetic 4P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S204-C40
ABB S204-C40 · thermal-magnetic 4P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · S204L-C63
ABB S204L-C63 · thermal-magnetic 4P breakerProtects the selected circuit against overload and short circuit. The current rating and trip curve must suit the load, conductors and installation.
ABB · 1SDA066765R1
ABB A1N 125 TMF 80-800 4p F F · 80 A · 4P molded-case breakerA four-pole molded-case breaker with fixed thermal overload protection at 80 A and fixed magnetic short-circuit threshold at 800 A. The 125 A frame is not the selected trip rating. No residual-current function is built in.
Hager · CFC225F
Hager CFC225F · 1P+N · 2P · 25 ACFC225F monitors leakage on 1P+N · 2P at 300 mA, Type AC. Its 25 A rating is the carrying current, not an overload-trip setting.
Hager · CFC240F
Hager CFC240F · 1P+N · 2P · 40 ACFC240F monitors leakage on 1P+N · 2P at 300 mA, Type AC. Its 40 A rating is the carrying current, not an overload-trip setting.
Hager · CFC263F
Hager CFC263F · 1P+N · 2P · 63 ACFC263F monitors leakage on 1P+N · 2P at 300 mA, Type AC. Its 63 A rating is the carrying current, not an overload-trip setting.
Hager · CFC440F
Hager CFC440F · 3P+N · 4P · 40 ACFC440F monitors leakage on 3P+N · 4P at 300 mA, Type AC. Its 40 A rating is the carrying current, not an overload-trip setting.
Hager · CFC463F
Hager CFC463F · 3P+N · 4P · 63 ACFC463F monitors leakage on 3P+N · 4P at 300 mA, Type AC. Its 63 A rating is the carrying current, not an overload-trip setting.
Hager · MW116
Hager MW116 · 1P · 16 AMW116 protects 1 poles against overloads and short circuits, with a C curve and 16 A rating. Match the circuit conductors and starting duty to this exact reference.
Hager · MV225
Hager MV225 · 2P · 25 AMV225 protects 2 poles against overloads and short circuits, with a B curve and 25 A rating. Match the circuit conductors and starting duty to this exact reference.
Hager · MV440
Hager MV440 · 4P · 40 AMV440 protects 4 poles against overloads and short circuits, with a B curve and 40 A rating. Match the circuit conductors and starting duty to this exact reference.
Hager · HMC380
Hager HMC380 · 3P · 80 AHMC380 protects 3 poles against overloads and short circuits, with a C curve and 80 A rating. This is a modular DIN-rail breaker, not a molded-case compact breaker.
Hager · HMC399
Hager HMC399 · 3P · 125 AHMC399 protects 3 poles against overloads and short circuits, with a C curve and 125 A rating. This is a modular DIN-rail breaker, not a molded-case compact breaker.
Hager · HMK499
Hager HMK499 · 4P · 125 AHMK499 protects 4 poles against overloads and short circuits, with a C curve and 125 A rating. This is a modular DIN-rail breaker, not a molded-case compact breaker.
Schneider Electric · EZ9F32263
Schneider EZ9F32263 · 2P C-curve breakerEasy9 EZ9F32263: 2 protected poles, 63 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · EZ9F32363
Schneider EZ9F32363 · 3P C-curve breakerEasy9 EZ9F32363: 3 protected poles, 63 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9N18365
Schneider A9N18365 · 3P C-curve breakerActi9 C120N A9N18365: 3 protected poles, 80 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9N18468
Schneider A9N18468 · 3P C-curve breakerActi9 C120H A9N18468: 3 protected poles, 80 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77225
Schneider A9F77225 · 2P C-curve breakerActi9 iC60N A9F77225: 2 protected poles, 25 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77240
Schneider A9F77240 · 2P C-curve breakerActi9 iC60N A9F77240: 2 protected poles, 40 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77320
Schneider A9F77320 · 3P C-curve breakerActi9 iC60N A9F77320: 3 protected poles, 20 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77325
Schneider A9F77325 · 3P C-curve breakerActi9 iC60N A9F77325: 3 protected poles, 25 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77340
Schneider A9F77340 · 3P C-curve breakerActi9 iC60N A9F77340: 3 protected poles, 40 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77363
Schneider A9F77363 · 3P C-curve breakerActi9 iC60N A9F77363: 3 protected poles, 63 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77440
Schneider A9F77440 · 4P C-curve breakerActi9 iC60N A9F77440: 4 protected poles, 40 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77450
Schneider A9F77450 · 4P C-curve breakerActi9 iC60N A9F77450: 4 protected poles, 50 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · A9F77463
Schneider A9F77463 · 4P C-curve breakerActi9 iC60N A9F77463: 4 protected poles, 63 A C curve. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV2P08
Schneider GV2P08 · motor breakerTeSys GV2P GV2P08: 3 protected poles, thermal adjustment 2.5–4 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV2P16
Schneider GV2P16 · motor breakerTeSys GV2P GV2P16: 3 protected poles, thermal adjustment 9–14 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV2P20
Schneider GV2P20 · motor breakerTeSys GV2P GV2P20: 3 protected poles, thermal adjustment 13–18 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV2P22
Schneider GV2P22 · motor breakerTeSys GV2P GV2P22: 3 protected poles, thermal adjustment 20–25 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV2ME16
Schneider GV2ME16 · motor breakerTeSys GV2ME GV2ME16: 3 protected poles, thermal adjustment 9–14 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV3P401
Schneider GV3P401 · motor breakerTeSys GV3P GV3P401: 3 protected poles, thermal adjustment 30–40 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV3P50
Schneider GV3P50 · motor breakerTeSys GV3P GV3P50: 3 protected poles, thermal adjustment 37–50 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV3P501
Schneider GV3P501 · motor breakerTeSys GV3P GV3P501: 3 protected poles, thermal adjustment 37–50 A. Thermal overload and magnetic short-circuit protection.
Schneider Electric · GV3P80
Schneider GV3P80 · motor breakerTeSys GV3P GV3P80: 3 protected poles, thermal adjustment 70–80 A. Thermal overload and magnetic short-circuit protection.
Suntree · SL7-63-NP-2P-C32-800V
Suntree SL7-63 · 2P · C32 · 800 V DCSL7-63 non-polarized 2P C32 breaker for a documented 800 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-4P-C32-1000V
Suntree SL7-63 · 4P · C32 · 1000 V DCSL7-63 non-polarized 4P C32 breaker for a documented 1000 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SRF-30-1000V
Suntree SRF-30 · 15 / 16 / 30 A · gPV · 1000 V DC10 × 38 mm photovoltaic gPV fuse links, 1000 V DC. Select the 15 A, 16 A or 30 A rating; the compatible holder is separate.
Suntree · SL7-63-NP-4P-C16-1000V
Suntree SL7-63 · 4P · C16 · 1000 V DCSL7-63 non-polarized 4P C16 breaker for a documented 1000 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-4P-C20-1000V
Suntree SL7-63 · 4P · C20 · 1000 V DCSL7-63 non-polarized 4P C20 breaker for a documented 1000 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-4P-C40-1000V
Suntree SL7-63 · 4P · C40 · 1000 V DCSL7-63 non-polarized 4P C40 breaker for a documented 1000 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-4P-C50-1000V
Suntree SL7-63 · 4P · C50 · 1000 V DCSL7-63 non-polarized 4P C50 breaker for a documented 1000 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-4P-C63-1000V
Suntree SL7-63 · 4P · C63 · 1000 V DCSL7-63 non-polarized 4P C63 breaker for a documented 1000 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-2P-C16-800V
Suntree SL7-63 · 2P · C16 · 800 V DCSL7-63 non-polarized 2P C16 breaker for a documented 800 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-2P-C50-800V
Suntree SL7-63 · 2P · C50 · 800 V DCSL7-63 non-polarized 2P C50 breaker for a documented 800 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SL7-63-NP-2P-C20-550V
Suntree SL7-63 · 2P · C20 · 550 V DCSL7-63 non-polarized 2P C20 breaker for a documented 550 V DC configuration. Thermal-magnetic interruption protects against qualifying overloads and short circuits.
Suntree · SM8-250HPV-2P-100A-1000V
Suntree SM8-250HPV/2 · 2P · 100 A · 1000 V DCSM8-250HPV/2 molded-case DC breaker: 250 A frame, 100 A rated current, two poles at 1000 V DC. Overload and instantaneous short-circuit protection; no C-curve rating is claimed.
Suntree · SM8-250HPV-2P-250A-1000V
Suntree SM8-250HPV/2 · 2P · 250 A · 1000 V DCSM8-250HPV/2 molded-case DC breaker: 250 A frame, 250 A rated current, two poles at 1000 V DC. Overload and instantaneous short-circuit protection; no C-curve rating is claimed.
Suntree · SRD-30-1P-30A-1100V
Suntree SRD-30 · 1P · 30 A max · 1100 V DCSRD-30 one-pole photovoltaic fuse holder, 30 A maximum at 1100 V DC, for separately selected 10 × 38 mm gPV links. The holder alone does not interrupt fault current. PV-0: do not open under load.
Suntree · SUP2-PV-2P-500V
Suntree SUP2-PV · 2P · 500 V DC · 20 / 40 kATwo-module photovoltaic surge protector, connected in parallel with the DC circuit. Diverts transient surges to protective earth; separate overcurrent protection is required. Uc and Up depend on the hardware revision, not the nominal 500 V designation alone.
Suntree · SUP2-PV-3P-1000V
Suntree SUP2-PV · 3P · 1000 V DC · 20 / 40 kAThree-module photovoltaic surge protector for one DC circuit, not three independent circuits. Connected in parallel, with a protective-earth path and separate overcurrent protection. Uc and Up depend on the hardware revision, not the nominal 1000 V designation alone.
Suntree · SUP1-40-4P-385V
Suntree SUP1-40 · 4P · Uc 385 V AC · 20 / 40 kAFour-module AC surge protector with L1, L2, L3 and N connections. Uc 385 V AC, In 20 kA, Imax 40 kA and Up ≤ 1.8 kV. Connected in parallel with separate backup protection; it is neither a circuit breaker nor a residual-current device.
Schneider Electric · LC1D806BD
Schneider LC1D806BD · 80 A contactorLC1D806BD switches three power poles: 80 A AC-3 at ≤440 V AC, with a 24 V DC coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D40AM7
Schneider LC1D40AM7 · 40 A contactorLC1D40AM7 switches three power poles: 40 A AC-3 at ≤440 V AC, with a 220 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D326BL
Schneider LC1D326BL · 32 A contactorLC1D326BL switches three power poles: 32 A AC-3 at ≤440 V AC, with a 24 V DC coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D150M7
Schneider LC1D150M7 · 150 A contactorLC1D150M7 switches three power poles: 150 A AC-3 at ≤440 V AC, with a 220 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D40AQ7
Schneider LC1D40AQ7 · 40 A contactorLC1D40AQ7 switches three power poles: 40 A AC-3 at ≤440 V AC, with a 380 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D50AM7
Schneider LC1D50AM7 · 50 A contactorLC1D50AM7 switches three power poles: 50 A AC-3 at ≤440 V AC, with a 220 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D25B7
Schneider LC1D25B7 · 25 A contactorLC1D25B7 switches three power poles: 25 A AC-3 at ≤440 V AC, with a 24 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D65AM7
Schneider LC1D65AM7 · 65 A contactorLC1D65AM7 switches three power poles: 65 A AC-3 at ≤440 V AC, with a 220 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D25M7
Schneider LC1D25M7 · 25 A contactorLC1D25M7 switches three power poles: 25 A AC-3 at ≤440 V AC, with a 220 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
Schneider Electric · LC1D95M7
Schneider LC1D95M7 · 95 A contactorLC1D95M7 switches three power poles: 95 A AC-3 at ≤440 V AC, with a 220 V AC 50/60 Hz coil. Preserve its exact connection and coil suffix.
KBE · KBE-SOLAR-DB-H1Z2Z2-K
KBE Solar DB 4–10 mm² H1Z2Z2-K DC Solar CableConfigurable single-core H1Z2Z2-K DC photovoltaic cable for string wiring between PV modules, DC isolation and protection, and inverter MPPT inputs.
Nexans · NEXANS-PV-DC-H1Z2Z2-K
Nexans PV-DC H1Z2Z2-K 4–10 mm² Solar CableMorocco-made single-core H1Z2Z2-K photovoltaic DC cable for string wiring, DC isolation and protection, and inverter MPPT inputs.
Ingelec · CM5402035
Ingelec Metalbox empty IP55 enclosure · 500 × 400 × 200 mmEmpty steel cabinet, 500 × 400 × 200 mm (height × width × depth), IP55 and IK10. Select the mounting plate and protection equipment separately.
Ingelec · CM6402635
Ingelec Metalbox empty IP55 enclosure · 600 × 400 × 260 mmEmpty steel cabinet, 600 × 400 × 260 mm (height × width × depth), IP55 and IK10. Select the mounting plate and protection equipment separately.
Ingelec · CM6502635
Ingelec Metalbox empty IP55 enclosure · 600 × 500 × 260 mmEmpty steel cabinet, 600 × 500 × 260 mm (height × width × depth), IP55 and IK10. Select the mounting plate and protection equipment separately.
Ingelec · CM7502635
Ingelec Metalbox empty IP55 enclosure · 700 × 500 × 260 mmEmpty steel cabinet, 700 × 500 × 260 mm (height × width × depth), IP55 and IK10. Select the mounting plate and protection equipment separately.
Ingelec · CM4302035
Ingelec Metalbox empty IP55 enclosure · 400 × 300 × 200 mmEmpty steel cabinet, 400 × 300 × 200 mm (height × width × depth), IP55 and IK10. Select the mounting plate and protection equipment separately.
Ingelec · CM8602635
Ingelec Metalbox empty IP55 enclosure · 800 × 600 × 260 mmEmpty steel cabinet, 800 × 600 × 260 mm (height × width × depth), IP55 and IK10. Select the mounting plate and protection equipment separately.
Ingelec · PP0504
Ingelec perforated plate for 500 × 400 mm MetalboxPerforated 2 mm galvanized steel mounting plate. Fits a 500 × 400 mm Metalbox; the plate itself measures 460 × 340 mm.
Ingelec · PP0605
Ingelec perforated plate for 600 × 500 mm MetalboxPerforated 2 mm galvanized steel mounting plate. Fits a 600 × 500 mm Metalbox; the plate itself measures 560 × 440 mm.
Ingelec · PP0705
Ingelec perforated plate for 700 × 500 mm MetalboxPerforated 2 mm galvanized steel mounting plate. Fits a 700 × 500 mm Metalbox; the plate itself measures 660 × 440 mm.
Ingelec · PP0604
Ingelec perforated plate for 600 × 400 mm MetalboxPerforated 2 mm galvanized steel mounting plate. Fits a 600 × 400 mm Metalbox; the plate itself measures 560 × 340 mm.
Ingelec · P6040
Ingelec white skirting trunking · 60 × 40 mmWhite RAL 9016 PVC skirting for surface cable routing, horizontally or vertically. Fittings and the optional separator are separate.
Ingelec · P6040E
Ingelec external corner for 60 × 40 mm skirtingExternal corner for Ingelec P6040 60 × 40 mm skirting. White RAL 9016 PVC; match the fitting to the cable route.
Ingelec · P6040I
Ingelec internal corner for 60 × 40 mm skirtingInternal corner for Ingelec P6040 60 × 40 mm skirting. White RAL 9016 PVC; match the fitting to the cable route.
Ingelec · P6040L
Ingelec flat corner for 60 × 40 mm skirtingFlat corner for Ingelec P6040 60 × 40 mm skirting. White RAL 9016 PVC; match the fitting to the cable route.
Ingelec · P6040T
Ingelec t junction for 60 × 40 mm skirtingT junction for Ingelec P6040 60 × 40 mm skirting. White RAL 9016 PVC; match the fitting to the cable route.
Ingelec · P6040S
Ingelec end cap for 60 × 40 mm skirtingEnd cap for Ingelec P6040 60 × 40 mm skirting. White RAL 9016 PVC; match the fitting to the cable route.
Ingelec · G4040
Ingelec slotted wiring duct with cover · 40 × 40 mmGrey PVC slotted duct, 40 × 40 mm, supplied with its cover in a 2 m length. Organizes wiring inside equipment cabinets.
Ingelec · G6040
Ingelec slotted wiring duct with cover · 60 × 40 mmGrey PVC slotted duct, 60 × 40 mm, supplied with its cover in a 2 m length. Organizes wiring inside equipment cabinets.
Ingelec · G6060
Ingelec slotted wiring duct with cover · 60 × 60 mmGrey PVC slotted duct, 60 × 60 mm, supplied with its cover in a 2 m length. Organizes wiring inside equipment cabinets.
Ingelec · G6080
Ingelec slotted wiring duct with cover · 60 × 80 mmGrey PVC slotted duct, 60 × 80 mm, supplied with its cover in a 2 m length. Organizes wiring inside equipment cabinets.
Ingelec · G8080
Ingelec slotted wiring duct with cover · 80 × 80 mmGrey PVC slotted duct, 80 × 80 mm, supplied with its cover in a 2 m length. Organizes wiring inside equipment cabinets.
Ingelec · 65/33N
Ingelec reinforced galvanized cable tray · 65 × 33 mmReinforced perforated steel tray, 65 × 33 mm (width × side height), in 3 m lengths. Galvanized Z275; supports and cover are separate.
Ingelec · 95/33N
Ingelec reinforced galvanized cable tray · 95 × 33 mmReinforced perforated steel tray, 95 × 33 mm (width × side height), in 3 m lengths. Galvanized Z275; supports and cover are separate.
Ingelec · 125/63N
Ingelec reinforced galvanized cable tray · 125 × 63 mmReinforced perforated steel tray, 125 × 63 mm (width × side height), in 3 m lengths. Galvanized Z275; supports and cover are separate.
Ingelec · 215/63N
Ingelec reinforced galvanized cable tray · 215 × 63 mmReinforced perforated steel tray, 215 × 63 mm (width × side height), in 3 m lengths. Galvanized Z275; supports and cover are separate.
Ingelec · 95/63N
Ingelec reinforced galvanized cable tray · 95 × 63 mmReinforced perforated steel tray, 95 × 63 mm (width × side height), in 3 m lengths. Galvanized Z275; supports and cover are separate.
Ingelec · 305/63N
Ingelec reinforced galvanized cable tray · 305 × 63 mmReinforced perforated steel tray, 305 × 63 mm (width × side height), in 3 m lengths. Galvanized Z275; supports and cover are separate.
Ingelec · 65/33NC
Ingelec cable tray cover · 65 × 33 mmGalvanized steel clip-on cover for the 65 × 33 mm cable-tray reference. Confirm the exact tray and delivered length before ordering.
Ingelec · 95/33NC
Ingelec cable tray cover · 95 × 33 mmGalvanized steel clip-on cover for the 95 × 33 mm cable-tray reference. Confirm the exact tray and delivered length before ordering.
Ingelec · 125/33NC
Ingelec cable tray cover · 125 × 33 mmGalvanized steel clip-on cover for the 125 × 33 mm cable-tray reference. Confirm the exact tray and delivered length before ordering.
Unbranded materials · RW-SANDWICH-30
Sandwich roofing panel · 30 mmInsulated roofing panel with a requested 30 mm core. Quotation per m², with panel dimensions and the supplied construction confirmed before ordering.
Unbranded materials · RW-SANDWICH-40
Sandwich roofing panel · 40 mmInsulated roofing panel with a requested 40 mm core. Quotation per m², with panel dimensions and the supplied construction confirmed before ordering.
Unbranded materials · RW-RAIL-GALV
Galvanized perforated steel railPerforated steel rail for mechanical mounting. Request the section and bar length; the quote confirms the supplied coating and fixing arrangement.
Unbranded materials · RW-RAIL-PREGALV
Pre-galvanized steel railSteel rail requested in a pre-galvanized finish. The supplier confirms the profile, perforations, coating and treatment of cut or fabricated areas.
Unbranded materials · RW-STEEL-H
Structural H-section steel · fer HH-section steel for a specified support structure. Confirm section designation, steel grade, length, finish and the structural design before ordering.
Unbranded materials · RW-BOLT
Steel boltsBolts for a specified mechanical joint. Match diameter, pitch, length, head type, strength class and coating to the joint design and mating nut.
Unbranded materials · RW-NUT
Steel nutsNuts for the specified bolt and joint. Match thread diameter and pitch, strength class, locking method and finish; a similar appearance does not establish a match.
Unbranded materials · RW-WASHER
Flat steel washersFlat washers for the specified mechanical joint. Confirm inner and outer diameters, thickness, material and finish; roof sealing washers are a separate selection.
Unbranded materials · RW-STEEL-SHEET
Single-skin steel roofing sheetSingle-skin steel roof covering quoted per m². The quote identifies the profile, sheet thickness, coating, lengths, useful width and billed surface.
RENEWAVEEnergy systems, held to standard.













































































































































































