    Suntree SUP2-PV · 3P · 1000 V DC · 20 / 40 kA

    Exact reference · SUP2-PV-3P-1000V

    Three-module photovoltaic surge protector for one DC circuit, not three independent circuits. Connected in parallel, with a protective-earth path and separate overcurrent protection. Uc and Up depend on the hardware revision, not the nominal 1000 V designation alone.

    Nominal discharge current In (8/20 µs)
    20 kA
    Maximum discharge current Imax (8/20 µs)
    40 kA
    Nominal DC designation
    1000 V DC
    Uc / Up
    Revision-dependent · not confirmed for supply
    Conductor arrangement
    DC + / DC − + PE

    The retained SUP2-PV family table and photographed hardware show different Uc / Up revisions. No single Uc or Up is assigned to this supply record. Select against cold-weather PV open-circuit voltage and equipment impulse withstand using the exact delivered nameplate and applicable manufacturer record. Do not treat the nominal DC designation as the permissible PV voltage.

    Pricing confirmed by quote

    Quote confirms reference and commercial terms; installation selection remains the installer’s responsibility.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    Three-module photovoltaic surge protector for one DC circuit, not three independent circuits. Connected in parallel, with a protective-earth path and separate overcurrent protection. Uc and Up depend on the hardware revision, not the nominal 1000 V designation alone.

    Relevant applications

    • PV combiner and inverter DC circuits

    Why ReneWave may shortlist it

    • Three-module photovoltaic surge protector for one DC circuit, not three independent circuits. Connected in parallel, with a protective-earth path and separate overcurrent protection. Uc and Up depend on the hardware revision, not the nominal 1000 V designation alone.

    What changes in practice

    • Connect the complete SPD assembly in parallel between DC +, DC − and the earth bar according to its terminal drawing. Three modules do not mean three PV strings or three switched poles. PE is always connected, never switched.
    • In is the nominal surge-discharge current and Imax the maximum surge-discharge current, both for an 8/20 µs pulse. They are not a 40 kA breaker rating. Coordinate backup protection, earth bonding and equipment impulse withstand; a rated backup fuse size is not established here.
    • Surge diversion only. No overload, short-circuit or residual-current protection; no protection guarantee against a direct lightning strike. Keep the circuit’s isolation and overcurrent devices separate.

    System position

    Parallel surge diversion, not series interruption.

    Surge diversion only. No overload, short-circuit or residual-current protection; no protection guarantee against a direct lightning strike. Keep the circuit’s isolation and overcurrent devices separate.

    The circuit supplies the load; the SPD is connected in parallel, not in series with the load.

    The load path stays separate from the parallel SPD branch. A surge travels through coordinated backup protection and the SPD to protective earth; PE continuity remains intact in both modes. The circuit supplies the load; the SPD is connected in parallel, not in series with the load.PV DC sourceSeparate DC equipmentIsolation / coordinationInverter DC inputSeparate conversionSeparate backup protectionSeparately coordinatedSUP2-PV 3P · 1000 V DCIn 20 / Imax 40 kA · 8/20 µsProtective earthPE · Always connected, never switchedThe load path stays separate from the parallel SPD branch. A surge travels through coordinated backup protection and the SPD to protective earth; PE continuity remains intact in both modes. The circuit supplies the load; the SPD is connected in parallel, not in series with the load.PV DC sourceSeparate DC equipmentIsolation / coordinationInverter DC inputSeparate conversionSeparate backup protectionSeparately coordinatedSUP2-PV 3P · 1000 V DCIn 20 / Imax 40 kA · 8/20 µsProtective earthPE · Always connected, never switchedThe load path stays separate from the parallel SPD branch. A surge travels through coordinated backup protection and the SPD to protective earth; PE continuity remains intact in both modes. The circuit supplies the load; the SPD is connected in parallel, not in series with the load.PV DC sourceSeparate DC equipmentIsolation / coordinationInverter DC inputSeparate conversionSeparate backup protectionSeparately coordinatedSUP2-PV 3P · 1000 V DCIn 20 / Imax 40 kA · 8/20 µsProtective earthPE · Always connected, never switched
    Read the technical explanation

    Three-module photovoltaic surge protector for one DC circuit, not three independent circuits. Connected in parallel, with a protective-earth path and separate overcurrent protection. Uc and Up depend on the hardware revision, not the nominal 1000 V designation alone.

    Connect the complete SPD assembly in parallel between DC +, DC − and the earth bar according to its terminal drawing. Three modules do not mean three PV strings or three switched poles. PE is always connected, never switched.

    Surge diversion only. No overload, short-circuit or residual-current protection; no protection guarantee against a direct lightning strike. Keep the circuit’s isolation and overcurrent devices separate.

    The retained SUP2-PV family table and photographed hardware show different Uc / Up revisions. No single Uc or Up is assigned to this supply record. Select against cold-weather PV open-circuit voltage and equipment impulse withstand using the exact delivered nameplate and applicable manufacturer record. Do not treat the nominal DC designation as the permissible PV voltage.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    Device identity and surge ratings

    Manufacturer reference

    SUP2-PV

    Selected configuration

    3P · 1000 V DC · In 20 kA / Imax 40 kA

    Circuit application

    DC · PV

    Catalog configuration ID

    SUP2-PV-3P-1000V

    Nominal discharge current In (8/20 µs)

    20 kA

    Maximum discharge current Imax (8/20 µs)

    40 kA

    Nominal DC designation

    1000 V DC

    Uc / Up

    Revision-dependent · not confirmed for supply

    Conductor arrangement

    DC + / DC − + PE

    03 · Selection points

    Four practical selection points.

    Match the circuit, surge ratings, earth connection and backup protection.

    1. 01

      Circuit and conductor arrangement

      Connect the complete SPD assembly in parallel between DC +, DC − and the earth bar according to its terminal drawing. Three modules do not mean three PV strings or three switched poles. PE is always connected, never switched.

    2. 02

      Voltage and surge ratings

      The retained SUP2-PV family table and photographed hardware show different Uc / Up revisions. No single Uc or Up is assigned to this supply record. Select against cold-weather PV open-circuit voltage and equipment impulse withstand using the exact delivered nameplate and applicable manufacturer record. Do not treat the nominal DC designation as the permissible PV voltage.

    3. 03

      Separate backup protection

      In is the nominal surge-discharge current and Imax the maximum surge-discharge current, both for an 8/20 µs pulse. They are not a 40 kA breaker rating. Coordinate backup protection, earth bonding and equipment impulse withstand; a rated backup fuse size is not established here.

    4. 04

      Mounting and earth connection

      35 mm DIN rail mounting inside a suitable enclosure. Keep the parallel conductors and PE connection short. Follow the supplied revision’s terminal drawing; isolate before replacing a module. A red status window calls for inspection and replacement, not automatic resetting.

    04 · Documentation

    Keep the exact reference traceable.

    Published documents for this exact reference support selection and handover.

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Separate equipment is selected for the installation; no automatic companions are added to your request.

    No automatic companion selection. Separate protection and accessories are chosen for the installation.

    Compare products
    ReneWave markRENEWAVE

    Energy systems, held to standard.