    ABB M202-32A 2P magnetic-only breaker

    Exact reference · M202-32A

    Short circuits, subject to the verified installation and breaking-capacity rating.

    Protection function
    Magnetic-only circuit breaker
    Rated current
    32 A
    Poles
    2
    ABB article
    2CDA282799R0321

    Does not provide thermal overload protection or residual-current (earth-leakage) protection.

    Pricing confirmed by quote

    The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    Short circuits, subject to the verified installation and breaking-capacity rating.

    Relevant applications

    • Circuits that already have correctly coordinated overload protection and need a magnetic short-circuit trip.

    Why ReneWave may shortlist it

    • Short circuits, subject to the verified installation and breaking-capacity rating.

    System position

    Example: an equipment circuit.

    Does not provide thermal overload protection or residual-current (earth-leakage) protection.

    Illustrative equipment circuit: the M202 handles short circuits. Separate overload protection must operate coordinated interruption equipment; this is not a wiring order or a sizing recommendation.

    Short circuits, subject to the verified installation and breaking-capacity rating. Illustrative equipment circuit: the M202 handles short circuits. Separate overload protection must operate coordinated interruption equipment; this is not a wiring order or a sizing recommendation.AC circuit supplyVoltage and fault level checkedM202-32A32 AOverload protectionCoordinated interruptionEquipment circuitLoad and conductors verifiedShort circuits, subject to the verified installation and breaking-capacity rating. Illustrative equipment circuit: the M202 handles short circuits. Separate overload protection must operate coordinated interruption equipment; this is not a wiring order or a sizing recommendation.AC circuit supplyVoltage and fault level checkedM202-32A32 AOverload protectionCoordinated interruptionEquipment circuitLoad and conductors verifiedShort circuits, subject to the verified installation and breaking-capacity rating. Illustrative equipment circuit: the M202 handles short circuits. Separate overload protection must operate coordinated interruption equipment; this is not a wiring order or a sizing recommendation.AC circuit supplyVoltage and fault level checkedM202-32A32 AOverload protectionCoordinated interruptionEquipment circuitLoad and conductors verified
    Read the technical explanation

    Does not provide thermal overload protection or residual-current (earth-leakage) protection.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    Device identity

    ABB reference

    M202-32A

    ABB article code

    2CDA282799R0321

    Product standard

    IEC/EN 60947-2

    03 · Confirm before quotation

    Four checks before this reference is quoted.

    ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

    1. 01

      Circuit function

      Confirm the circuit needs magnetic-only short-circuit protection.

    2. 02

      Overload coordination

      Confirm the upstream or downstream overload device and coordination.

    3. 03

      Fault level and conductors

      Check supply voltage, prospective fault current, conductors and the installation standard.

    4. 04

      Exact ABB article

      Confirm the delivered ABB article code against the written quote.

    04 · Documentation

    Keep the exact reference traceable.

    Published documents for this exact reference support selection and handover.

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.

    No additional equipment is published for this reference. Required accessories are confirmed during quotation.

    Compare products
    ReneWave markRENEWAVE

    Energy systems, held to standard.