ABB IN FH202 40 A / 30 mA Type AC RCCB
Exact reference · IN FH202 40A-30mA/AC
Residual-current faults of the Type AC waveform at a rated sensitivity of 30 mA.
- Protection function
- Residual-current device (RCCB)
- Rated current
- 40 A · 30 mA · Type AC
- Poles
- 2
- ABB article
- 1SYF202006R1400
Does not provide overload or short-circuit protection; coordinate a separate overcurrent device.
Pricing confirmed by quote
The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.
Availability confirmed in your written quote
01 · Product role
What this product does in the system.
Residual-current faults of the Type AC waveform at a rated sensitivity of 30 mA.
Relevant applications
- AC circuits requiring 30 mA Type AC residual-current protection where the load and local rules permit that type.
Why ReneWave may shortlist it
- Residual-current faults of the Type AC waveform at a rated sensitivity of 30 mA.
System position
Example: a resistive heating circuit.
Does not provide overload or short-circuit protection; coordinate a separate overcurrent device.
Illustrative non-electronic resistive load: the FH202 detects sinusoidal AC leakage. Verify Type AC suitability and local rules; electronic controls, drives and solar equipment need a separately reviewed RCD type. Separate overcurrent protection is mandatory.
Read the technical explanation
Does not provide overload or short-circuit protection; coordinate a separate overcurrent device.
02 · Specifications
Ratings, dimensions and practical consequence.
Device identity
- ABB reference
IN FH202 40A-30mA/AC
- ABB article code
1SYF202006R1400
- Product standard
IEC/EN 61008
03 · Confirm before quotation
Four checks before this reference is quoted.
ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.
- 01

Type AC suitability
Check whether Type AC is suitable for the connected loads and local requirements.
- 02

Overcurrent coordination
Coordinate a separate overcurrent device; 40 A is the rated current, not an overload trip.
- 03

Current and wiring
Verify rated current, supply voltage and conductors against the actual circuit.
- 04

Exact ABB article
Confirm the delivered ABB article code; the gallery shows the FH202 family, not the exact order-code label.
04 · Documentation
Keep the exact reference traceable.
Published documents for this exact reference support selection and handover.
05 · Complete the system
Accessories and adjacent equipment, in one request.
Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.
No additional equipment is published for this reference. Required accessories are confirmed during quotation.