    Front view of the Huawei SUN2000-8K-MAP0 inverter in a Huawei product presentation
    Front view · verified SUN2000-MAP0 family hardware with exact 8 kW, two-MPPT and LUNA-interface facts.
    Huawei FusionSolarPremium

    Huawei SUN2000 8 kW Three-Phase Hybrid Solar Inverter

    Exact reference · SUN2000-8K-MAP0

    An 8 kW three-phase hybrid inverter combining two PV trackers, bidirectional Huawei storage control and a documented SmartGuard backup path. The battery, SmartGuard, meter, external protection and optional communications equipment remain separate.

    Three-phase output
    8,000 W · 3W/N+PE

    Defines the AC output class; it does not approve the site service or connected loads.

    PV design allowance
    14,600 Wp recommended maximum

    Cold voltage, operating current and string allocation still govern the array.

    PV tracking
    2 MPPTs · 1 input each

    Two suitable string groups can be tracked independently.

    MPPT window
    160–1,000 V

    Each string must remain within the operating window across expected temperatures.

    Backup path
    SmartGuard-63A-T0 · ≤20 ms published

    Backup requires separate compatible equipment, firmware and commissioned settings.

    Do not select this inverter from 8 kW alone. Confirm the three-phase service, cold string voltage, module current, storage design, backup loads and commissioned grid settings.

    Pricing confirmed by quote

    The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    The SUN2000-8K-MAP0 converts power from two designed photovoltaic string inputs into grid-synchronised three-phase AC. It also manages compatible Huawei LUNA storage through its battery interface and can support a separate SmartGuard backup architecture. Those external components are not included with the inverter.

    Relevant applications

    • Three-phase residential solar systems with a calculated two-string array
    • Projects planning compatible Huawei LUNA2000 S0 or S1 storage
    • Sites requiring a separately designed three-phase SmartGuard backup path

    Why ReneWave may shortlist it

    • Two MPPTs can manage two separately calculated photovoltaic operating points.
    • The bidirectional interface supports reviewed Huawei LUNA S0 and S1 storage architectures.
    • SmartGuard-63A-T0 can provide a documented three-phase backup route when the complete design supports it.
    • FusionSolar keeps commissioning, monitoring and alarm follow-up in one ecosystem.

    Built-in capabilities

    Four functions, read before the headline specifications.

    Two PV operating points

    Two MPPTs can track two separately calculated string groups.

    Each tracker accepts one string input with a 16 A operating-current and 22 A short-circuit-current limit.

    Solar DC becomes three-phase AC

    The inverter converts photovoltaic DC into synchronised three-phase AC for protected distribution.

    Rated output is 8,000 W at 220/380 V, 230/400 V or 240/415 V, 3W/N+PE.

    Huawei storage can be integrated

    Supported LUNA2000 S0 or S1 storage connects through the bidirectional battery interface.

    Exact battery, firmware, metering, charge limits and SmartGuard architecture require project validation.

    Commissioning stays visible

    Integrated WLAN and RS485 support FusionSolar commissioning, monitoring and alarm follow-up.

    Ethernet and cellular communication require optional compatible equipment.

    Inside the energy system

    One inverter. Different energy paths.

    Solar conversion inside the inverter. Storage, external protection and configured load circuits remain separate.

    PV strings pass through both MPPT stages and the inverter to serve protected three-phase site loads. The utility remains the direct AC reference.

    The diagram separates five documented operating states for the Huawei SUN2000-8K-MAP0. Solar can supply protected three-phase site loads or charge compatible Huawei LUNA storage. The battery can support the site, and commissioned settings can permit utility charging. During an outage, photovoltaic and battery power reach selected three-phase backup loads only through a separate SmartGuard-63A-T0. PV strings pass through both MPPT stages and the inverter to serve protected three-phase site loads. The utility remains the direct AC reference.Two designedPV stringsone input per MPPTlimits verifiedTwo integratedMPPTs160–1,000 V window16 A eachSUN20008K-MAP0three-phase hybrid controlProtected ACdistributionmeter + protectionThree-phasesite loadsprotected demandHuawei LUNA2000S0 or S1600–980 V · separateUtility supplydirect AC referencegrid code verifiedThe diagram separates five documented operating states for the Huawei SUN2000-8K-MAP0. Solar can supply protected three-phase site loads or charge compatible Huawei LUNA storage. The battery can support the site, and commissioned settings can permit utility charging. During an outage, photovoltaic and battery power reach selected three-phase backup loads only through a separate SmartGuard-63A-T0. PV strings pass through both MPPT stages and the inverter to serve protected three-phase site loads. The utility remains the direct AC reference.Two designedPV stringsone input per MPPTlimits verifiedTwo integratedMPPTs160–1,000 V window16 A eachSUN20008K-MAP0three-phase hybrid controlProtected ACdistributionmeter + protectionThree-phasesite loadsprotected demandHuawei LUNA2000S0 or S1600–980 V · separateUtility supplydirect AC referencegrid code verifiedThe diagram separates five documented operating states for the Huawei SUN2000-8K-MAP0. Solar can supply protected three-phase site loads or charge compatible Huawei LUNA storage. The battery can support the site, and commissioned settings can permit utility charging. During an outage, photovoltaic and battery power reach selected three-phase backup loads only through a separate SmartGuard-63A-T0. PV strings pass through both MPPT stages and the inverter to serve protected three-phase site loads. The utility remains the direct AC reference.Two designed PV stringsone input per MPPTTwo integrated MPPTs160–1,000 V · 16 A eachSUN2000 · 8K-MAP0three-phase hybrid controlProtected 3-phase distributionmeter + project protectionThree-phase site loadsprotected demandHuawei LUNA S0 / S1600–980 V · separate equipmentUtility supplydirect AC reference · grid codeverified

    Active power path Inactive path

    Conceptual operation, not a wiring plan. Separate equipment, protection, firmware and commissioning must be verified.

    Read the technical explanation

    More three-phase capacity within Huawei’s reviewed solar, storage and backup architecture.

    The SUN2000-8K-MAP0 combines two photovoltaic trackers, three-phase solar conversion and a bidirectional Huawei battery interface. Batteries, SmartGuard, metering, external protection and optional communications remain separate equipment.

    Storage and backup are designed paths

    Compatible LUNA2000 S0 or S1 storage can be integrated after the exact battery, firmware, meter and operating settings are confirmed. Three-phase backup requires a separate SmartGuard-63A-T0 and a load design that remains inside the published operating limits.

    Array design still controls

    The 14.6 kWp recommended PV allowance does not approve an array by itself. Each string must remain inside the 160–1,000 V operating window and the published current limits across expected site temperatures.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    PV input

    Recommended maximum PV power

    14,600 Wp

    Maximum input voltage

    1,100 V

    Start and rated voltage

    160 V · 600 V

    Operating range

    160–1,000 V

    MPPT inputs

    2 trackers · 1 input each

    Current limits

    16 A maximum per MPPT · 22 A maximum Isc

    Three-phase AC output

    Rated and maximum apparent power

    8,000 W · 8,800 VA

    Maximum output current

    13.3 A

    Nominal voltage

    220/380 V · 230/400 V · 240/415 V · 3W/N+PE

    Efficiency

    98.6% maximum · 98.0% European weighted

    Asymmetric operation

    100% three-phase asymmetric load supported

    Storage and backup interface

    Compatible storage family

    Huawei LUNA2000 S0 / S1

    Battery operating range

    600–980 V

    Maximum battery current

    20 A

    Maximum charging power

    12,000 W

    Maximum discharging power

    8,800 W

    Backup device

    SmartGuard-63A-T0 · separate equipment

    Automatic switchover

    ≤20 ms under published compatible conditions

    Installation and communications

    Enclosure and cooling

    IP66 · natural convection

    Dimensions

    490 × 460 × 130 mm including bracket

    Weight

    21 kg including bracket

    Communications

    Integrated WLAN · RS485 · optional WLAN-FE or 4G Smart Dongle

    03 · Confirm before quotation

    Four checks before this reference is quoted.

    ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

    1. 01

      PV strings

      Confirm cold Voc, operating voltage, current, module count, shading and allocation across both MPPTs.

    2. 02

      Three-phase AC

      Confirm the site service, 3W/N+PE arrangement, 50 Hz grid code, anti-islanding, protection and project export-control requirements.

    3. 03

      Battery and backup

      Confirm the exact LUNA S0/S1 reference, firmware, battery limits, metering, SmartGuard and selected backup-load capacity.

    4. 04

      Installation and monitoring

      Confirm temperature derating, clearances, AC/DC protection, earthing, FusionSolar ownership and optional communications equipment.

    04 · Documents & warranty

    Keep the exact reference traceable.

    Documents shown here support selection and handover. The accepted order and exact manufacturer warranty document control.

    Verified document record

    Complete applicable record at review date

    Morocco / global residential documentation · English and French · reviewed 2026-08-17

    The current family datasheet, user documentation and applicable warranty policy are retained as verified local Huawei PDFs. Exact delivered hardware, firmware and market documents are reconfirmed in the written quotation; ReneWave Customer Care handles document and warranty assistance.

    SUN2000-(5K-12K)-MAP0 Datasheetdatasheet · Global family record · EnglishVersion 202601 · product family
    View PDF Download PDF
    SUN2000-(5K-12K)-MAP0 User Manualmanual · Global · EnglishIssue 13 · 2026-06-30 · product family
    View PDF Download PDF
    SUN2000-(5K-12K)-MAP0 Quick Guideinstallation · Global · English / multilingualIssue 13 · product family
    View PDF Download PDF
    Huawei Residential Smart PV Warranty Policy V2.1warranty · Global policy · order-specific terms apply · EnglishIssue 04 · 2025-11-30 · product family
    View PDF Download PDF

    Manufacturer warranty reference

    10 years · current residential Smart PV policy

    • Manufacturer commercial warranty subject to the current policy and supplied product record
    • ReneWave Customer Care manages document and warranty assistance
    Customer Care

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.

    Recommended companions

    CHINT DTSU666-H 100 A Three-Phase Smart Power Sensor

    CHINT · DTSU666-H-100A

    CHINT DTSU666-H 100 A Three-Phase Smart Power Sensor

    Adds three-phase current, voltage, power and energy measurement for a compatible Huawei control architecture. Confirm service current, CT direction and location, phase sequence, RS485 settings, firmware and the commissioned export-control architecture.

    Compare products
    1
    ReneWave markRENEWAVE

    Energy systems, held to standard.

    ReneWave updates · You choose the topics

    Solar, maintenance, practical guides and selected offers.

    Pick one stream or several. Offers stay separate from editorial updates, and every email includes a one-click unsubscribe.

    Choose your updates

    Let’s redefine energy
    together.

    Engineer-led Solar delivery and audit-led maintenance for Moroccan homes, hospitality, agriculture, industry and professional buildings.

    Start a conversation

    Services

    • All Services
    • ReneWave Solar
    • ReneWcare Max
    • Start a Solar Project
    • Start a ReneWcare Assessment

    Store & Tools

    • Equipment Store
    • Solar Calculator
    • Maintenance Priorities
    • Record a Breakdown
    • All Tools

    Knowledge

    • Knowledge Hub
    • Journal
    • Newsroom
    • FAQ
    • Technical Library
    • Applications
    • Solar Technology
    • Maintenance Technology
    • Brand Partners
    • Energy Audit Playbook

    Company

    • Our Company
    • Our Mission
    • Meet Us
    • Engineering Method
    • Contact
    • Support, Warranty & Returns
    • Terms & Policies

    © 2026 ReneWave Morocco / All rights reserved

    Terms of SaleWarrantiesReturns & RefundsDelivery & InstallationPrivacy & CookiesClaims & After-Sales
    Engineering-led / Made in Morocco
    Edit with