Front view of the Huawei SUN2000-3KTL-L1 inverter in the approved Huawei product presentation
    Front view · SUN2000-3KTL-L1 with verified 3 kW, two-MPPT and battery-interface facts.
    Huawei FusionSolarPremium

    Huawei SUN2000 3 kW Single-Phase Solar Inverter

    Exact reference · SUN2000-3KTL-L1

    A compact 3 kW single-phase solar inverter with two MPPTs, optional Huawei high-voltage storage integration and FusionSolar monitoring. The complete PV, AC, metering, storage and backup architecture is confirmed before quotation.

    Rated AC output
    3,000 W single phase

    Defines the inverter output class, not the permitted PV string design.

    PV design allowance
    4,500 Wp recommended maximum

    The exact module count still follows voltage and current limits.

    PV tracking
    2 MPPTs · 1 input each

    Two suitable string groups can be tracked separately.

    MPPT window
    90–560 V

    String operating voltage must remain inside the usable range.

    Input current
    12.5 A per MPPT · 18 A Isc

    Modern high-current modules require explicit compatibility review.

    Do not select a 3 kW inverter from nominal power alone. Confirm string behavior, AC service, grid requirements, battery intent and backup expectations.

    Pricing confirmed by quote

    The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    The SUN2000-3KTL-L1 receives DC power from two designed photovoltaic string inputs and converts it into grid-synchronised single-phase AC for the site. It can interface with supported Huawei storage and monitoring equipment, but those functions require separate hardware, compatible firmware and commissioned settings.

    Relevant applications

    • Residential single-phase photovoltaic systems
    • Small professional sites with a verified 220/230/240 V single-phase service
    • Roofs where two suitable string groups benefit from separate MPPT tracking

    Why ReneWave may shortlist it

    • Two MPPTs can manage two separately calculated PV operating points.
    • The compact IP65 enclosure uses natural convection and integrated WLAN.
    • Supported Huawei storage can be added through a separately validated architecture.
    • FusionSolar provides commissioning, monitoring and alarm visibility.

    Built-in capabilities

    Four functions, read before the headline specifications.

    Two PV operating points

    Two MPPTs can track two separately calculated string groups or roof orientations.

    Each MPPT accepts one input with a published 12.5 A maximum current and 18 A short-circuit-current limit.

    Solar DC becomes site AC

    The inverter converts photovoltaic DC into synchronised single-phase AC for the protected site distribution.

    Rated output is 3,000 W at 220/230/240 Vac and 50/60 Hz.

    Storage can be added

    A supported Huawei Smart String ESS can connect through the dedicated battery interface after exact-system validation.

    Battery model, firmware, current limits and backup equipment remain separate confirmation items.

    Commissioning stays visible

    Integrated WLAN and RS485 support FusionSolar commissioning, monitoring and alarm follow-up.

    Ethernet and cellular paths require an optional compatible Smart Dongle.

    Inside the energy system

    One inverter. Different energy paths.

    Solar conversion inside the inverter. Storage, external protection and configured load circuits remain separate.

    PV strings pass through both MPPT stages and the inverter to serve protected site loads. The utility remains the AC reference, not an export destination.

    The diagram separates five documented operating states for the Huawei SUN2000-3KTL-L1. Solar can supply protected site loads or charge a compatible Huawei battery. The battery can support site loads, and commissioned settings can permit charging from the utility. During an outage, photovoltaic and battery power reach selected loads only through separate compatible backup switching equipment. PV strings pass through both MPPT stages and the inverter to serve protected site loads. The utility remains the AC reference, not an export destination.Two designedPV stringsone input per MPPTlimits verifiedTwo integratedMPPTs90–560 V window12.5 A eachSUN20003KTL-L1single-phase conversionProtected ACdistributionproject protectionSingle-phasesite loadsprotected demandCompatible HuaweiSmart String ESSmodel + firmwareUtility supplyAC referencegrid code verifiedThe diagram separates five documented operating states for the Huawei SUN2000-3KTL-L1. Solar can supply protected site loads or charge a compatible Huawei battery. The battery can support site loads, and commissioned settings can permit charging from the utility. During an outage, photovoltaic and battery power reach selected loads only through separate compatible backup switching equipment. PV strings pass through both MPPT stages and the inverter to serve protected site loads. The utility remains the AC reference, not an export destination.Two designedPV stringsone input per MPPTlimits verifiedTwo integratedMPPTs90–560 V window12.5 A eachSUN20003KTL-L1single-phase conversionProtected ACdistributionproject protectionSingle-phasesite loadsprotected demandCompatibleHuawei ESSmodel + firmwareUtility supplyAC referencegrid code verifiedThe diagram separates five documented operating states for the Huawei SUN2000-3KTL-L1. Solar can supply protected site loads or charge a compatible Huawei battery. The battery can support site loads, and commissioned settings can permit charging from the utility. During an outage, photovoltaic and battery power reach selected loads only through separate compatible backup switching equipment. PV strings pass through both MPPT stages and the inverter to serve protected site loads. The utility remains the AC reference, not an export destination.Two designed PV stringsone input per MPPTTwo integrated MPPTs90–560 V · 12.5 A eachSUN2000 · 3KTL-L1single-phase conversionProtected AC distributionproject protection appliesSingle-phase site loadsprotected demandCompatible Huawei ESSmodel + firmware · separate equipmentUtility supplyAC reference · grid code verified
    Read the technical explanation

    Two MPPTs for a carefully designed single-phase solar system.

    The SUN2000-3KTL-L1 converts power from two designed photovoltaic string inputs into grid-synchronised single-phase AC. The two trackers can be useful for separately calculated roof orientations or string groups, but they do not remove the need to verify voltage, current, shading and module count.

    Battery and backup boundary

    The inverter provides an interface for supported Huawei Smart String ESS configurations. The battery is separate, and backup supply requires the validated battery architecture plus separate switching equipment such as the Backup Box-B0. Metering, export-control equipment and optional communications dongles are also confirmed from the complete project.

    Selection consequence

    The 3 kW rating is the inverter's nominal AC output. It is not an annual-production estimate and does not by itself approve the photovoltaic array, AC connection or backup design.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    PV input

    Recommended maximum PV power

    4,500 Wp

    Maximum input voltage

    600 V

    Start voltage

    100 V

    MPPT operating range

    90–560 V

    MPPT inputs

    2 trackers · 1 input each

    Current limits

    12.5 A maximum per MPPT · 18 A maximum Isc

    AC output

    Rated output

    3,000 W single phase

    Maximum apparent power

    3,300 VA

    Maximum output current

    15 A

    Nominal voltage and frequency

    220/230/240 Vac · 50/60 Hz

    Efficiency

    98.3% maximum · 97.3% European weighted

    Installation and communications

    Enclosure

    IP65 · natural convection

    Dimensions

    365 × 365 × 156 mm including bracket

    Weight

    12 kg including bracket

    Communications

    Integrated WLAN · RS485 · optional WLAN-FE or 4G Smart Dongle

    03 · Confirm before quotation

    Four checks before this reference is quoted.

    ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

    1. 01

      PV strings

      Confirm cold Voc, operating voltage, current, module count, shading, orientation and the allocation of one input to each MPPT.

    2. 02

      AC connection

      Confirm the 220/230/240 V single-phase service, 50 Hz grid code, anti-islanding, AC protection and project-specific export-control method.

    3. 03

      Battery and backup

      Confirm the exact Huawei ESS, firmware, charge/discharge limits, Backup Box-B0 and selected backup-load demand.

    4. 04

      Installation and monitoring

      Confirm the IP65 location, temperature derating, external protection, meter, communications path and FusionSolar commissioning ownership.

    04 · Documents & warranty

    Keep the exact reference traceable.

    Documents shown here support selection and handover. The accepted order and exact manufacturer warranty document control.

    Manufacturer warranty reference

    10 years · current global SUN2000-L1 policy for other markets

    • Manufacturer commercial warranty subject to the current policy and supplied product record
    • ReneWave Customer Care manages document and warranty assistance
    Customer Care

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.

    Recommended companions

    CHINT DTSU666-H 100 A Three-Phase Smart Power Sensor

    CHINT · DTSU666-H-100A

    CHINT DTSU666-H 100 A Three-Phase Smart Power Sensor

    Adds three-phase current, voltage, power and energy measurement for a compatible Huawei control architecture. Conditional only where the project has a documented three-phase 3P3W/3P4W measurement architecture despite the inverter being single-phase.

    Compare products
    ReneWave markRENEWAVE

    Energy systems, held to standard.