Hager MV225 · 2P · 25 A
Exact reference · MV225
MV225 protects 2 poles against overloads and short circuits, with a B curve and 25 A rating. Match the circuit conductors and starting duty to this exact reference.
- Protection function
- Thermal-magnetic breaker
- Pole arrangement
- 2P
- Rated current
- 25 A
Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.
Pricing confirmed by quote
Quote confirms reference and commercial terms; installation selection remains the installer’s responsibility.
Availability confirmed in your written quote
01 · Product role
What this product does in the system.
MV225 protects 2 poles against overloads and short circuits, with a B curve and 25 A rating. Match the circuit conductors and starting duty to this exact reference.
Relevant applications
- Selected commercial distribution or equipment circuits, matched to the documented supply and protection function.
Why ReneWave may shortlist it
- MV225 protects 2 poles against overloads and short circuits, with a B curve and 25 A rating. Match the circuit conductors and starting duty to this exact reference.
System position
AC protection: conceptual single-line view.
Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.
The closed device supplies L1 / L2. Downstream branch protection remains separate. PE bypasses every switched pole.
Read the technical explanation
Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.
02 · Specifications
Ratings, dimensions and practical consequence.
Device identity
- Hager reference
MV225
- Manufacturer EAN
3250614522253
- Protection function
Thermal-magnetic breaker
- Pole arrangement
2P
- Rated current
25 A
- Rated operational voltage
400 V AC
- Trip curve
B
- Neutral
Two protected poles: the example uses L1 and L2, not a one-protected-pole plus neutral device.
Electrical ratings
- Icn · IEC 60898-1
3 kA · IEC 60898-1
- Ui
500 V
- Uimp
4 kV
- Frequency
50–60 Hz
- IP
IP20
Mounting and connections
- Modules / width
2 / 35 mm
- Dimensions H × W × D
83 × 35 × 70 mm
- Terminal torque
2.8 Nm
03 · Selection points
Four practical selection points.
Choose by circuit function, conductors and documented electrical limits.
- 01

Pole arrangement
Two protected poles: the example uses L1 and L2, not a one-protected-pole plus neutral device.
- 02

Current and protection function
Curve B: match starting currents and conductor protection to the 25 A rating. Ambient temperature affects the available continuous current; use the Hager derating table.
- 03

Voltage and fault capacity
Icn 3 kA follows IEC 60898-1. The exact current record has no separate voltage-specific capacity table; do not infer higher capacities or an Icu value.
- 04

Mounting and connections
DIN-rail mounting, 2 modules / 35 mm wide. Follow the manufacturer's terminals and installation instructions. Nominal terminal torque: 2.8 Nm.
04 · Documentation
Keep the exact reference traceable.
Published documents for this exact reference support selection and handover.
05 · Complete the system
Accessories and adjacent equipment, in one request.
Separate equipment is selected for the installation; no automatic companions are added to your request.
No automatic companion selection. Separate protection and accessories are chosen for the installation.