Four designed PV inputs
Two MPPTs can each accept two calculated string inputs.
Huawei publishes 30 A per MPPT with two strings, 20 A with one string and 40 A maximum short-circuit current.

Exact reference · SUN2000-15K-MB0
A 15 kW three-phase hybrid inverter with four PV inputs across two MPPTs and two Huawei storage terminals. Batteries, SmartGuard, metering, external protection, selected backup circuits and optional communications hardware remain separate.
Defines the rated AC output class; it does not approve the site service or connected loads.
String voltage, per-input current and combined MPPT current still govern the array.
Two inputs per tracker permit designed parallel strings, not four arbitrary strings.
The exact batteries, firmware and one- or two-string limits require project validation.
Backup requires separate compatible switching, commissioned settings and a controlled load design.
Do not select the 15 kW reference from nominal power alone. Confirm the three-phase service, string allocation, combined MPPT current, battery architecture, backup demand and commissioned grid settings.
Pricing confirmed by quote
The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.
Availability confirmed in your written quote
01 · Product role
The SUN2000-15K-MB0 converts power from up to four deliberately allocated PV strings into grid-synchronised three-phase AC. Its two battery terminals can manage one or two compatible Huawei LUNA storage strings, while backup requires a separate SmartGuard-63A-T0. None of that separate equipment is included with the inverter.
Relevant applications
Why ReneWave may shortlist it
Built-in capabilities
Two MPPTs can each accept two calculated string inputs.
Huawei publishes 30 A per MPPT with two strings, 20 A with one string and 40 A maximum short-circuit current.

The inverter converts photovoltaic DC into synchronised three-phase AC for protected distribution.
Rated output is 15,000 W, with 16,500 VA maximum apparent power.

Two storage terminals support validated Huawei LUNA2000 S0 or S1 architectures.
Huawei publishes 21 kW maximum charging with one battery string, 25 kW with two and 16.5 kW maximum discharge.

Integrated WLAN and RS485 support FusionSolar commissioning, monitoring and alarm follow-up.
Ethernet and cellular communication require optional compatible equipment.
Inside the energy system
Solar conversion inside the inverter. Storage, external protection and configured load circuits remain separate.
Four designed string inputs pass through two MPPTs and the MB0 to serve protected three-phase site loads. Utility remains the direct AC reference.
More solar and storage capacity for a deliberately engineered three-phase system.
The SUN2000-15K-MB0 combines four PV inputs, two trackers, three-phase conversion and two Huawei storage terminals. LUNA storage, SmartGuard, metering, external protection, selected backup circuits and optional communications remain separate equipment.
Four inputs still require electrical design
Two strings can share one MPPT only when each string and the combined tracker remain inside Huawei's voltage, current and short-circuit limits. Physical connector count is not compatibility evidence.
Storage and backup remain complete-system decisions
One or two compatible LUNA strings can be integrated after exact models, firmware, current limits and commissioning settings are confirmed. With MB0, the separate SmartGuard-63A-T0 backup port supplies selected single-phase loads only; three-phase loads remain on non-backup outputs.
02 · Specifications
22,500 Wp
1,100 V
200 V · 600 V
200–1,000 V · 410–800 V full load
2 MPPTs · 4 inputs total
30 A per MPPT with two strings · 20 A with one · 40 A maximum Isc
15,000 W · 16,500 VA
21.7 A
23.9 A
220/380 V · 230/400 V · 240/415 V · 3W/N+PE
98.4% maximum · 98.0% European weighted
2 · Huawei LUNA2000 S0 / S1
600–980 V · 26.25 A maximum per string
21 kW one string · 25 kW two strings
16.5 kW
15 kW documented maximum
SmartGuard-63A-T0 · ≤100 ms · selected single-phase loads only
IP66 · smart-air cooling
546 × 460 × 228 mm
21 kg
Integrated WLAN · RS485 · optional WLAN-FE or 4G dongle
03 · Confirm before quotation
ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

Confirm cold Voc, operating voltage, module count and both per-string and combined-MPPT current for all four inputs.

Confirm the service, 3W/N+PE arrangement, 50 Hz grid code, anti-islanding, protection and project export-control requirements.

Confirm exact LUNA S0/S1 references, firmware, one- or two-string limits, metering, SmartGuard and the selected single-phase backup circuits.

Confirm smart-air cooling clearances, temperature derating, AC/DC protection, earthing, FusionSolar ownership and optional communications.
04 · Documents & warranty
Documents shown here support selection and handover. The accepted order and exact manufacturer warranty document control.
10 years · current residential Smart PV policy
05 · Complete the system
Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.