Front presentation of the Deye SUN-20K-SG05LP3-EU-SM2 three-phase hybrid inverter
    Front view · official 14–20 kW family enclosure with verified 20 kW, 2+2 PV-input and 350 A storage-interface facts.
    DeyeBest Value

    Deye SUN 20 kW Three-Phase Low-Voltage Hybrid Inverter

    Exact reference · SUN-20K-SG05LP3-EU-SM2

    A 20 kW three-phase hybrid inverter integrating two PV trackers, two low-voltage battery inputs, selected-load output and one configurable generator port. The batteries, BMS, metering, protection and generator remain separate.

    AC output
    20,000 W rated · 22,000 VA maximum

    Service capacity, continuous current, phase allocation and surge behavior still require calculation.

    PV design boundary
    40,000 W access · 32,000 W input

    The complete array must satisfy power, voltage, current and clipping checks.

    PV allocation
    2 MPPTs · 4 inputs arranged 2+2

    Four connectors remain grouped behind two trackers and are not four independent channels.

    Battery interface
    2 inputs · 40–60 V · 350 A aggregate

    Both battery paths, BMS records, conductors and protection must support the intended operating current.

    Three-phase behavior
    100% unbalanced · max 50% rated per phase

    Selected loads and each phase must be designed deliberately.

    Do not select this inverter from 20 kW, three-phase output or 48 V alone. Confirm string current, battery and BMS behavior, AC service, phase loads, surge demand, pass-through current and GEN-port assignment.

    Pricing confirmed by quote

    The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    The SUN-20K-SG05LP3-EU-SM2 receives four designed PV inputs grouped behind two MPPTs, converts solar or battery DC into controlled three-phase AC and coordinates a separately protected load output. Utility, generator and storage operation depend on separate equipment, protection and commissioned settings.

    Relevant applications

    • Higher-demand three-phase homes, hospitality and professional sites requiring coordinated solar and 48 V storage
    • Arrays suited to four designed string inputs grouped two per MPPT
    • Projects with deliberately selected protected loads and a separately engineered generator path

    Why ReneWave may shortlist it

    • Two MPPTs coordinate two separately calculated operating groups with two inputs each.
    • Two 40–60 V battery inputs support a published 350 A aggregate charge/discharge ceiling.
    • The three-phase output publishes 100% unbalanced operation, with each phase limited to 50% of rated output.
    • The configurable GEN port can perform one commissioned role at a time.

    Built-in capabilities

    Four functions, read before the headline specifications.

    Two calculated PV operating points

    Two MPPTs track two separately calculated groups using four inputs arranged 2+2.

    Each tracker publishes 36 A operating and 54 A short-circuit-current limits.

    20 kW three-phase conversion

    Available PV or battery power is converted into controlled three-phase AC.

    Rated output is 20,000 W with 22,000 VA maximum apparent power.

    Dual-input 48 V storage

    Two inputs connect a separately validated 40–60 V battery architecture.

    The published aggregate charge and discharge limit is 350 A.

    Grid, backup and GEN control

    Grid, protected-load and configurable GEN interfaces coordinate valid operating states.

    The GEN port is assigned one commissioned function at a time.

    Inside the energy system

    One inverter. Different energy paths.

    Solar conversion inside the inverter. Storage, external protection and configured load circuits remain separate.

    PV passes through two MPPTs and the inverter to serve selected protected three-phase loads.

    The GEN port is configured for one role at a time. This diagram shows generator input only in Generator support mode.

    Six operating states show four designed PV inputs arranged two plus two behind two MPPTs and the Deye 20 kW three-phase hybrid inverter. It can serve selected loads, charge or discharge separate 48 V storage, accept conditional utility charging or use a separately configured generator input. Utility and generator input are never active together. PV passes through two MPPTs and the inverter to serve selected protected three-phase loads.Four designedPV string inputs2+2 allocationlimits verifiedTwo integratedMPPTs160–650 V36 A eachDeye SUN20K-SG05LP3-EU-SM2hybrid · three phaseProtected loadoutput70 A pass-throughprotection separateSelectedthree-phase loadsphase demand + surgeverifiedCompatible 48 Vbattery systemtwo inputs · 350 AThree-phase utilitygrid portmetered separatelyGeneratorconfigured GEN portseparate equipmentSix operating states show four designed PV inputs arranged two plus two behind two MPPTs and the Deye 20 kW three-phase hybrid inverter. It can serve selected loads, charge or discharge separate 48 V storage, accept conditional utility charging or use a separately configured generator input. Utility and generator input are never active together. PV passes through two MPPTs and the inverter to serve selected protected three-phase loads.Four designedPV string inputs2+2 allocationlimits verifiedTwo integratedMPPTs160–650 V36 A eachDeye SUN · 20K SM2hybrid · three phaseProtected output70 A path verifiedSelected site loadsphase demand verified48 V battery systemtwo inputs · 350 AThree-phase utilitygrid portmetered separatelyGeneratorconfigured GEN portseparate equipmentSix operating states show four designed PV inputs arranged two plus two behind two MPPTs and the Deye 20 kW three-phase hybrid inverter. It can serve selected loads, charge or discharge separate 48 V storage, accept conditional utility charging or use a separately configured generator input. Utility and generator input are never active together. PV passes through two MPPTs and the inverter to serve selected protected three-phase loads.Four designed PV inputs2+2 allocation · limits verifiedTwo integrated MPPTs160–650 V · 36 A eachDeye SUN20K SM2hybrid · three phaseProtected load output70 A path · protectedSelected site loadsphase demand verifiedCompatible 48 V batterytwo inputs · 350 AThree-phase utilitygrid port · metered separatelyGeneratorconfigured GEN port · separate
    Read the technical explanation

    Higher-output three-phase solar, 48 V storage and selected-load backup.

    The Deye SUN-20K-SG05LP3-EU-SM2 combines two photovoltaic trackers, three-phase conversion, two low-voltage battery inputs and a protected-load output. Four PV connectors remain grouped behind two MPPTs. The complete system still requires validated storage, BMS records, metering, protection and commissioned settings.

    Functional boundary

    The GEN port is configurable and performs one role at a time. Two battery inputs do not establish universal battery compatibility, and unbalanced output does not remove the need to calculate phase loads, conductors and protection.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    PV input

    PV access / input power

    40,000 W access · 32,000 W input

    Trackers and inputs

    2 MPPTs · 4 inputs arranged 2+2

    Voltage range

    160–650 V MPPT · 800 V maximum · 160 V startup

    Current limits

    36 A operating · 54 A Isc per MPPT

    Three-phase AC

    Rated / maximum output

    20,000 W · 22,000 VA

    Rated / maximum current

    30.4/29 A · 33.4/31.9 A at 380/400 V

    Efficiency

    97.6% maximum · 97.0% European weighted

    Unbalanced output

    100% · maximum 50% rated output per phase

    Battery and control

    Battery inputs and range

    2 inputs · 40–60 V

    Charge / discharge current

    350 A maximum aggregate

    AC pass-through

    70 A continuous

    Generator interface

    Configurable GEN port · one role at a time

    Enclosure

    Dimensions

    456 × 750 × 268.5 mm excluding connectors and brackets

    Weight

    51.9 kg

    Protection and cooling

    IP65 · intelligent air cooling

    Parallel operation

    Up to 10 units under documented conditions

    03 · Confirm before quotation

    Four checks before this reference is quoted.

    ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

    1. 01

      PV strings and MPPT allocation

      Confirm cold Voc, operating voltage, 36 A operating current, 54 A Isc, module count and exact 2+2 allocation.

    2. 02

      Storage and phase loads

      Confirm 40–60 V behavior, chemistry, BMS, two-input arrangement, 350 A aggregate path, usable capacity, per-phase demand and surge.

    3. 03

      Three-phase AC architecture

      Confirm service capacity, 70 A pass-through path, phase allocation, selected circuits, conductors, protection, earthing and cooling clearance.

    4. 04

      GEN port and commissioning

      Confirm the single GEN-port role, CT or meter direction, firmware, communications, parallel settings and operating schedule.

    04 · Documents & warranty

    Keep the exact reference traceable.

    Documents shown here support selection and handover. The accepted order and exact manufacturer warranty document control.

    Manufacturer warranty reference

    5 years standard · extension only when ordered

    • Manufacturer inverter warranty subject to market, serial, installation and accepted order
    • ReneWave Customer Care manages the retained documents and case route
    Customer Care

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.

    No additional equipment is published for this reference. Required accessories are confirmed during quotation.

    Compare products
    ReneWave markRENEWAVE

    Energy systems, held to standard.