    Hager MV440 · 4P · 40 A

    Exact reference · MV440

    MV440 protects 4 poles against overloads and short circuits, with a B curve and 40 A rating. Match the circuit conductors and starting duty to this exact reference.

    Protection function
    Thermal-magnetic breaker
    Pole arrangement
    4P
    Rated current
    40 A

    Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.

    Pricing confirmed by quote

    Quote confirms reference and commercial terms; installation selection remains the installer’s responsibility.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    MV440 protects 4 poles against overloads and short circuits, with a B curve and 40 A rating. Match the circuit conductors and starting duty to this exact reference.

    Relevant applications

    • Selected commercial distribution or equipment circuits, matched to the documented supply and protection function.

    Why ReneWave may shortlist it

    • MV440 protects 4 poles against overloads and short circuits, with a B curve and 40 A rating. Match the circuit conductors and starting duty to this exact reference.

    System position

    AC protection: conceptual single-line view.

    Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.

    The closed device supplies L1 / L2 / L3 / N. Downstream branch protection remains separate. PE bypasses every switched pole.

    MV440 protects 4 poles against overloads and short circuits, with a B curve and 40 A rating. Match the circuit conductors and starting duty to this exact reference. The closed device supplies L1 / L2 / L3 / N. Downstream branch protection remains separate. PE bypasses every switched pole.AC circuit supplyL1 / L2 / L3 / NMV44040 A · BCommercial distributionSeparate branch protectionSelected site circuitsLoad / conductors selectedMV440 protects 4 poles against overloads and short circuits, with a B curve and 40 A rating. Match the circuit conductors and starting duty to this exact reference. The closed device supplies L1 / L2 / L3 / N. Downstream branch protection remains separate. PE bypasses every switched pole.AC circuit supplyL1 / L2 / L3 / NMV44040 A · BCommercial distributionSeparate branch protectionSelected site circuitsLoad / conductors selectedMV440 protects 4 poles against overloads and short circuits, with a B curve and 40 A rating. Match the circuit conductors and starting duty to this exact reference. The closed device supplies L1 / L2 / L3 / N. Downstream branch protection remains separate. PE bypasses every switched pole.AC circuit supplyL1 / L2 / L3 / NMV44040 A · BCommercial distributionSeparate branch protectionSelected site circuitsLoad / conductors selected
    Read the technical explanation

    Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    Device identity

    Hager reference

    MV440

    Manufacturer EAN

    3250614524400

    Protection function

    Thermal-magnetic breaker

    Pole arrangement

    4P

    Rated current

    40 A

    Rated operational voltage

    230–400 V AC

    Trip curve

    B

    Neutral

    Four protected poles in the MV/MW family catalogue. The example switches L1, L2, L3 and N; PE stays separate.

    Electrical ratings

    Icn · IEC 60898-1

    3 kA · IEC 60898-1

    Ui

    500 V

    Uimp

    4 kV

    Frequency

    50–60 Hz

    IP

    IP20

    Mounting and connections

    Modules / width

    4 / 70 mm

    Dimensions H × W × D

    83 × 70 × 70 mm

    Terminal torque

    2.8 Nm

    03 · Selection points

    Four practical selection points.

    Choose by circuit function, conductors and documented electrical limits.

    1. 01

      Pole arrangement

      Four protected poles in the MV/MW family catalogue. The example switches L1, L2, L3 and N; PE stays separate.

    2. 02

      Current and protection function

      Curve B: match starting currents and conductor protection to the 40 A rating. Ambient temperature affects the available continuous current; use the Hager derating table.

    3. 03

      Voltage and fault capacity

      Icn 3 kA follows IEC 60898-1. The exact current record has no separate voltage-specific capacity table; do not infer higher capacities or an Icu value.

    4. 04

      Mounting and connections

      DIN-rail mounting, 4 modules / 70 mm wide. Follow the manufacturer's terminals and installation instructions. Nominal terminal torque: 2.8 Nm.

    04 · Documentation

    Keep the exact reference traceable.

    Published documents for this exact reference support selection and handover.

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Separate equipment is selected for the installation; no automatic companions are added to your request.

    No automatic companion selection. Separate protection and accessories are chosen for the installation.