ABB XT2N 160 Ekip LS/I · 100 A · 3P
Exact reference · XT2N 160 Ekip LS/I In=100A 3p F F
L protects against overload; short-circuit protection is selected as delayed S or instantaneous I, not both simultaneously. No G function is claimed.
- Protection function
- Electronic overload + S or I short-circuit protection
- Poles
- 3
- Rated current
- 100 A
No integrated residual-current protection. Use separately selected earth-leakage protection where required.
Pricing confirmed by quote
Quote confirms reference and commercial terms; installation selection remains the installer’s responsibility.
Availability confirmed in your written quote
01 · Product role
What this product does in the system.
L protects against overload; short-circuit protection is selected as delayed S or instantaneous I, not both simultaneously. No G function is claimed.
Relevant applications
- Selected three-phase commercial or equipment circuits.
Why ReneWave may shortlist it
- L protects against overload; short-circuit protection is selected as delayed S or instantaneous I, not both simultaneously. No G function is claimed.
System position
Three-phase AC circuit: conceptual single-line view.
No integrated residual-current protection. Use separately selected earth-leakage protection where required.
The selected three-phase circuit is supplied through the closed device. Separate equipment is illustrative, not included or automatically recommended.
Read the technical explanation
No integrated residual-current protection. Use separately selected earth-leakage protection where required.
02 · Specifications
Ratings, dimensions and practical consequence.
Device identity
- ABB reference
XT2N 160 Ekip LS/I In=100A 3p F F
- ABB article code
1SDA067057R1
- Protection function
Electronic overload + S or I short-circuit protection
- Poles
3
- Rated current
100 A
- Rated operational voltage
690 V AC · IEC/EN 60947-2
- Trip unit / frame
100 A trip unit · 160 A frame
Breaking capacity by voltage
- Icu · IEC/EN 60947-2
65 kA · 220 / 230 / 240 V AC; 36 kA · 380 / 415 / 440 V AC; 30 kA · 500 V AC; 20 kA · 525 V AC; 10 kA · 690 V AC
- Ics · IEC/EN 60947-2
65 kA · 220 / 230 / 240 V AC; 36 kA · 380 / 415 / 440 V AC; 30 kA · 500 V AC; 20 kA · 525 V AC; 10 kA · 690 V AC
03 · Selection points
Four practical selection points.
Match the device to the circuit, expected load and fault conditions. Request a quote for the exact reference you have selected.
- 01

Pole configuration
Three protected poles for L1, L2 and L3. No neutral pole: do not substitute it for a 3P+N or 4P device.
- 02

Current and trip function
L protects against overload; short-circuit protection is selected as delayed S or instantaneous I, not both simultaneously. No G function is claimed.
- 03

Voltage and fault capacity
Compare the prospective fault current with the capacity at the actual supply voltage and standard. Icn, Icu and Ics are different ratings, not interchangeable labels.
- 04

Connections and trip settings
Fixed installation with front terminals. Set L and choose S or I using ABB’s trip-unit instructions; 160 A is the frame, not the 100 A trip-unit rating.
04 · Documentation
Keep the exact reference traceable.
Published documents for this exact reference support selection and handover.
05 · Complete the system
Accessories and adjacent equipment, in one request.
Separate equipment is selected for the installation; no automatic companions are added to your request.
No automatic companion selection. Separate protection and accessories are chosen for the installation.