    Dyness S51100 STACK100 battery module in a realistic front and side angled presentation
    Battery module · authenticated exact-SKU hardware photography, corroborated against the current Dyness STACK100 datasheet and V2.9 manual.
    DynessBest Value

    Dyness S51100 STACK100 5.12 kWh High-Voltage Battery Module

    Exact reference · S51100

    Five kilowatt-hours of modular LiFePO4 storage for a controlled Dyness STACK100 high-voltage cluster.

    Module energy
    5.12 kWh nominal · 4.864 kWh usable

    Complete cluster energy depends on using three to fifteen modules under Dyness test conditions.

    Module electrical rating
    51.2 V · 100 Ah

    This is one series module inside a high-voltage stack, not a standalone 48 V battery.

    Current limits
    50 A recommended · 100 A continuous

    The published 125 A peak applies for two minutes at 25°C.

    Required architecture
    3–15 S51100 + SBDU100

    The module cannot operate or connect to an inverter independently.

    Installation boundary
    IP20 · indoor

    Use a clean, supported and environmentally suitable indoor location.

    Do not select this module from 5.12 kWh, 51.2 V or STACK100 branding alone. Confirm the 3–15-module series stack, SBDU100, base architecture, inverter protocol and firmware, current limits, indoor environment and commissioning records.

    Pricing confirmed by quote

    The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    The S51100 is the cell-containing storage module in a Dyness STACK100 cluster. Three to fifteen modules connect in series through their documented composite interfaces and operate behind the mandatory SBDU100 controller and a separately validated high-voltage inverter.

    Relevant applications

    • Indoor commercial high-voltage storage systems
    • STACK100 clusters requiring 3–15 S51100 modules
    • Projects retaining exact inverter, module, controller and commissioning records

    Why ReneWave may shortlist it

    • Adds 5.12 kWh nominal energy per documented STACK100 module.
    • Uses LiFePO4 cells and a cable-free stacking interface.
    • Supports a controlled 15.36–76.8 kWh cluster behind SBDU100.

    Built-in capabilities

    Four functions, read before the headline specifications.

    Stores 5.12 kWh nominal energy

    One S51100 contributes 4.864 kWh usable energy under Dyness test conditions.

    A complete STACK100 cluster requires three to fifteen modules.

    Contains LiFePO4 cells

    Sixteen 3.2 V / 100 Ah cells form the documented 51.2 V module.

    The SBDU100, not this module, provides cluster control and inverter communication.

    Uses cable-free series stacking

    Male and female composite interfaces connect modules within the reviewed stack.

    Base arrangement and locating features must follow the installation manual.

    Adds integrated fire protection

    The current STACK100 record specifies a built-in aerosol fire extinguisher.

    Room-level fire protection and installation requirements remain separate.

    System position

    Where this battery module sits in a STACK100 storage system.

    Three to fifteen S51100 modules store energy behind the required SBDU100 and a compatible high-voltage inverter. One module cannot connect to AC loads or operate independently. Physical equipment: the required standard or documented expansion base is separate from an S51100 module and does not act as an electrical-flow node.

    PV supplies protected site loads through the compatible inverter while the STACK100 cluster remains idle.

    PV and utility sources connect through a separately selected compatible high-voltage inverter and protected AC distribution. Three to fifteen S51100 modules charge and discharge through the mandatory SBDU100. The physical base is separate equipment. No direct PV-to-module, module-to-AC-load, standalone backup or grid-export path is shown. PV supplies protected site loads through the compatible inverter while the STACK100 cluster remains idle.PV arrayseparate equipmentCompatible high-voltage inverter / chargerprotocol + firmware confirmedProtected AC distributionproject protection separateProtected site loadsserved through inverterRequired Dyness SBDU100separate controller + base3–15 Dyness S51100 modules15.36–76.8 kWh nominalUtility supplyconditional charging sourcePV and utility sources connect through a separately selected compatible high-voltage inverter and protected AC distribution. Three to fifteen S51100 modules charge and discharge through the mandatory SBDU100. The physical base is separate equipment. No direct PV-to-module, module-to-AC-load, standalone backup or grid-export path is shown. PV supplies protected site loads through the compatible inverter while the STACK100 cluster remains idle.PV arrayseparate equipmentCompatible high-voltage inverter / chargerprotocol + firmware confirmedProtected AC distributionproject protection separateProtected site loadsserved through inverterRequired Dyness SBDU100separate controller + base3–15 Dyness S51100 modules15.36–76.8 kWh nominalUtility supplyconditional charging sourcePV and utility sources connect through a separately selected compatible high-voltage inverter and protected AC distribution. Three to fifteen S51100 modules charge and discharge through the mandatory SBDU100. The physical base is separate equipment. No direct PV-to-module, module-to-AC-load, standalone backup or grid-export path is shown. PV supplies protected site loads through the compatible inverter while the STACK100 cluster remains idle.PV arrayseparate equipmentCompatible HV inverter / chargerseparate conversion equipmentProtected AC distributionseparate protectionProtected site loadsAC loadsRequired Dyness SBDU100separate controller3–15 Dyness S51100 modulesSTACK100 battery clusterUtility supplyconditional source

    Electrical powerInactive / conditional

    Conceptual system position, not an installation drawing. Separate equipment and commissioning must be verified.

    What’s included

    Inside the manufacturer box

    • 1×S51100 battery module
    • 4×M5x30 flat-head Phillips screws
    Read the technical explanation

    Five kilowatt-hours of modular LiFePO4 storage for a controlled Dyness STACK100 high-voltage cluster.

    The S51100 contains the battery cells and contributes 5.12 kWh nominal and 4.864 kWh usable energy. It is not a standalone low-voltage battery. Three to fifteen modules form a series stack behind one required SBDU100 and a separately validated high-voltage inverter.

    System boundary

    The correct base architecture, inverter voltage window, communication protocol, firmware, current limits, indoor installation and commissioning record are confirmed before quotation.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    S51100 battery module

    Cell technology

    LiFePO4 · 16 × 3.2 V / 100 Ah cells

    Nominal energy

    5.12 kWh

    Usable energy

    4.864 kWh

    Nominal voltage

    51.2 V

    Nominal capacity

    100 Ah

    Dimensions

    590 × 390 × 133.5 mm

    Weight

    47 kg

    Enclosure

    IP20 · indoor

    Current and power boundaries

    Recommended current

    50 A · 0.5C

    Maximum continuous current

    100 A · 1C

    Peak discharge

    125 A for 2 minutes at 25°C

    Recommended power

    2.56 kW charge / discharge

    Maximum power

    5.12 kW charge / discharge

    Complete STACK100 dependency

    Module count

    3–15 × S51100

    Required controller

    1 × SBDU100

    Nominal cluster energy

    15.36–76.8 kWh

    Usable cluster energy

    14.592–72.96 kWh

    Cycle record

    ≥8,000 under Dyness test conditions

    03 · Confirm before quotation

    Four checks before this reference is quoted.

    ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

    1. 01

      Stack composition

      Confirm 3–15 S51100 modules, one SBDU100 and the correct standard or documented expansion-base arrangement.

    2. 02

      Inverter and communication

      Confirm exact inverter voltage window, Dyness protocol, firmware, cable and pinout.

    3. 03

      Current and installation

      Confirm 50 A recommended, 100 A continuous and 125 A two-minute limits, plus support, protection, conductors and IP20 indoor conditions.

    4. 04

      Traceability and commissioning

      Record every module and controller serial, firmware, stack configuration, communication state and delivered warranty pack.

    04 · Documents & warranty

    Keep the exact reference traceable.

    Documents shown here support selection and handover. The accepted order and exact manufacturer warranty document control.

    Verified document record

    Complete applicable record at review date

    Global technical record · Morocco order qualification · English · reviewed 2026-08-29

    The May 2026 STACK100 datasheet, V2.9 user manual, August 2026 compatibility list and exact component warranty are verified official PDFs retained locally. No separate certificate or UN38.3 card is published because no additional official exact-scope PDF passed the document gate.

    Dyness STACK100 Datasheetdatasheet · Global technical record · English2026-05-20 · product family
    View PDF Download PDF
    Dyness STACK100 User Manualmanual · Global · EnglishV2.9 · 2025-07 · product family
    View PDF Download PDF
    Dyness STACK100 Inverter Compatibility Listcompatibility · Global · English2026-08-25 · product family
    View PDF Download PDF
    Dyness STACK100 Component Warrantywarranty · Worldwide manufacturer terms · English202410 · published 2025-02 · exact reference
    View PDF Download PDF

    Manufacturer warranty reference

    10 years

    • The retained component warranty explicitly lists S51100
    • Exact serial, communication state, installation and delivered warranty terms control
    Customer Care

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.

    Required interfaces and add-ons

    Dyness SBDU100 STACK100 High-Voltage Battery Controller & Floor Base

    Dyness · SBDU100

    Dyness SBDU100 STACK100 High-Voltage Battery Controller & Floor Base
    Compare products
    1
    ReneWave markRENEWAVE

    Energy systems, held to standard.

    ReneWave updates · You choose the topics

    Solar, maintenance, practical guides and selected offers.

    Pick one stream or several. Offers stay separate from editorial updates, and every email includes a one-click unsubscribe.

    Choose your updates

    Let’s redefine energy
    together.

    Engineer-led Solar delivery and audit-led maintenance for Moroccan homes, hospitality, agriculture, industry and professional buildings.

    Start a conversation

    Services

    • All Services
    • ReneWave Solar
    • ReneWcare Max
    • Start a Solar Project
    • Start a ReneWcare Assessment

    Store & Tools

    • Equipment Store
    • Solar Calculator
    • Maintenance Priorities
    • Record a Breakdown
    • All Tools

    Knowledge

    • Knowledge Hub
    • Journal
    • Newsroom
    • FAQ
    • Technical Library
    • Applications
    • Solar Technology
    • Maintenance Technology
    • Brand Partners
    • Energy Audit Playbook

    Company

    • Our Company
    • Our Mission
    • Meet Us
    • Engineering Method
    • Contact
    • Support, Warranty & Returns
    • Terms & Policies

    © 2026 ReneWave Morocco / All rights reserved

    Terms of SaleWarrantiesReturns & RefundsDelivery & InstallationPrivacy & CookiesClaims & After-Sales
    Engineering-led / Made in Morocco
    Edit with