Front presentation of the Deye SUN-10K-SG02LP1-EU-AM3 hybrid inverter
    Front view · approved Deye presentation with verified 10 kW, three-MPPT and 220 A battery-interface facts.
    DeyeBest Value

    Deye SUN 10 kW Single-Phase Low-Voltage Hybrid Inverter

    Exact reference · SUN-10K-SG02LP1-EU-AM3

    A higher-output single-phase hybrid inverter integrating three PV trackers, solar conversion, a bidirectional 48 V battery inverter/charger and a dedicated selected-load output. Battery, BMS, generator, metering, protection and installation remain separate.

    AC output
    10,000 W rated · 11,000 VA maximum

    Selected-load demand, continuous current and surge behavior still require calculation.

    PV design boundary
    20,000 W access · 16,000 W input

    The two published PV figures describe different limits; the complete array must satisfy every voltage, current and clipping check.

    PV allocation
    3 MPPTs · 2 inputs per tracker

    Six connectors remain grouped behind three trackers and cannot accept six arbitrary strings.

    Battery interface
    40–60 V · 220 A charge/discharge

    Battery, BMS, conductors and protection must support the intended continuous and transient current safely.

    Off-grid peak
    2× rated power for 10 seconds

    This is a short published condition, not permission to place the complete site on the protected output.

    Do not select this inverter from 10 kW or 48 V alone. Confirm PV current, battery current capability, BMS protocol, selected-load demand, surge behavior, AC service and GEN-port assignment.

    Pricing confirmed by quote

    The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    The SUN-10K-SG02LP1-EU-AM3 receives DC power through six designed string inputs grouped behind three MPPTs, converts it into single-phase AC and can charge or discharge a separately selected 48 V battery. Its dedicated load output can support selected circuits during an outage. Utility, generator, battery and load paths still require external protection, compatible equipment and commissioned settings.

    Relevant applications

    • Higher-demand single-phase sites requiring coordinated solar and 48 V storage
    • Arrays needing three separately calculated MPPT groups with up to two strings per tracker
    • Projects with selected essential loads and a separately engineered generator input path

    Why ReneWave may shortlist it

    • Three MPPTs can coordinate three separately calculated PV operating groups.
    • The 40–60 V battery interface publishes a 220 A charge and discharge ceiling for a deliberately engineered current path.
    • A dedicated load output can support selected protected circuits when utility power is unavailable.
    • The configurable GEN port can perform one commissioned role at a time.

    Built-in capabilities

    Four functions, read before the headline specifications.

    Three PV operating points

    Three MPPTs track three separately calculated PV groups.

    Each tracker provides two inputs and is limited to 26 A operating current and 44 A short-circuit current.

    Single-phase solar conversion

    Available PV power is converted into controlled 220/230 V single-phase AC.

    Rated output is 10,000 W with 11,000 VA maximum apparent power.

    High-current 48 V storage

    The inverter can charge and discharge a separately selected 40–60 V battery system.

    The published maximum charge and discharge current is 220 A.

    Grid, backup and GEN-port control

    Dedicated grid, protected-load and configurable GEN interfaces coordinate valid operating states.

    The GEN port is assigned one commissioned function at a time.

    Inside the energy system

    One inverter. Different energy paths.

    Solar conversion inside the inverter. Storage, external protection and configured load circuits remain separate.

    PV passes through three MPPTs and the inverter to serve the selected protected-load circuit.

    The GEN port is configured for one role at a time. This diagram shows generator input only in Generator support mode.

    Six operating states show six designed PV inputs grouped behind three MPPTs and the Deye 10 kW hybrid inverter. The inverter can serve selected loads, charge or discharge a separate 48 V battery, accept conditional utility charging or use a separately configured generator input. Utility and generator input are never active together. PV passes through three MPPTs and the inverter to serve the selected protected-load circuit.Six designedPV string inputstwo per MPPTlimits verifiedThree integratedMPPTs150–425 V26 A eachDeye SUN10K-SG02LP1-EU-AM3hybrid · single phaseProtected loadoutputdedicated circuitprotection separateSelectedsite loadsdemand + surgeverifiedCompatible 48 Vbattery system40–60 V · 220 A pathUtility supplygrid portmetered separatelyGeneratorconfigured GEN portseparate equipmentSix operating states show six designed PV inputs grouped behind three MPPTs and the Deye 10 kW hybrid inverter. The inverter can serve selected loads, charge or discharge a separate 48 V battery, accept conditional utility charging or use a separately configured generator input. Utility and generator input are never active together. PV passes through three MPPTs and the inverter to serve the selected protected-load circuit.Six designedPV string inputstwo per MPPTlimits verifiedThree integratedMPPTs150–425 V26 A eachDeye SUN10K-SG02LP1-EU-AM3hybrid · single phaseProtected outputseparate load circuitSelected site loadsdemand + surge verified48 V battery system40–60 V · 220 A pathUtility supplygrid portmetered separatelyGeneratorconfigured GEN portseparate equipmentSix operating states show six designed PV inputs grouped behind three MPPTs and the Deye 10 kW hybrid inverter. The inverter can serve selected loads, charge or discharge a separate 48 V battery, accept conditional utility charging or use a separately configured generator input. Utility and generator input are never active together. PV passes through three MPPTs and the inverter to serve the selected protected-load circuit.Six designed PV inputstwo per MPPT · limits verifiedThree integrated MPPTs150–425 V · 26 A eachDeye SUN · 10K-SG02LP1-EU-AM3hybrid · single phaseProtected load outputdedicated circuit · protectedSelected site loadsdemand + surge verifiedCompatible 48 V battery40–60 V · 220 A pathUtility supplygrid port · metered separatelyGeneratorconfigured GEN port · separate
    Read the technical explanation

    Higher single-phase output with three trackers and a high-current 48 V storage interface.

    The Deye SUN-10K-SG02LP1-EU-AM3 combines three photovoltaic trackers, single-phase conversion, a bidirectional low-voltage battery inverter/charger and a dedicated protected-load output. Six PV connectors remain grouped behind three MPPTs. The complete system still requires the correct battery, BMS, metering, external protection and commissioned settings.

    Functional boundary

    The GEN port is configurable. It cannot be generator input, smart-load output and AC-coupling input at the same time. Backup capability applies to the deliberately selected and protected load circuit, not automatically to every site load.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    PV input

    PV access / input power

    20,000 W access · 16,000 W input

    Trackers and inputs

    3 MPPTs · 2 inputs each

    Voltage range

    150–425 V MPPT · 500 V maximum · 125 V startup

    Current limits

    26 A operating · 44 A Isc per MPPT

    Single-phase AC

    Rated / maximum apparent output

    10,000 W · 11,000 VA

    Nominal service

    220/230 V · L+N+PE · 50/60 Hz

    Efficiency

    97.6% maximum · 96.5% European weighted

    Off-grid peak

    2× rated power for 10 seconds

    Battery and control

    Battery range

    40–60 V · lead-acid or compatible lithium

    Charge / discharge current

    220 A maximum

    Generator interface

    Configurable GEN port · one role at a time

    Parallel operation

    Up to 16 documented units under validated conditions

    Enclosure

    Dimensions

    420 × 670 × 233 mm

    Weight

    35.6 kg

    Protection and cooling

    IP65 · intelligent air cooling

    Published noise

    <45 dB

    03 · Confirm before quotation

    Four checks before this reference is quoted.

    ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

    1. 01

      PV strings and MPPTs

      Confirm cold Voc, operating voltage, 26 A combined operating current, 44 A Isc, module count and two-string allocation per tracker.

    2. 02

      Battery and selected loads

      Confirm 40–60 V battery behavior, chemistry, BMS, 220 A current path, usable capacity, load demand and surge.

    3. 03

      AC and protection architecture

      Confirm utility service, dedicated protected circuits, isolation, conductors, protection, earthing and fan-cooling clearances.

    4. 04

      GEN port and commissioning

      Confirm the single GEN-port role, CT or meter direction, firmware, communications, parallel settings and operating schedule.

    04 · Documents & warranty

    Keep the exact reference traceable.

    Documents shown here support selection and handover. The accepted order and exact manufacturer warranty document control.

    Manufacturer warranty reference

    5 years standard · extension only when ordered

    • Manufacturer inverter warranty subject to market, serial, installation and accepted order
    • ReneWave Customer Care manages the retained documents and case route
    Customer Care

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.

    No additional equipment is published for this reference. Required accessories are confirmed during quotation.

    Compare products
    ReneWave markRENEWAVE

    Energy systems, held to standard.