MW116: official Hager hardware view, with original manufacturer markings unchanged.
    MW116: official Hager hardware view, with original manufacturer markings unchanged.
    HagerBest Value

    Hager MW116 · 1P · 16 A

    Exact reference · MW116

    MW116 protects 1 poles against overloads and short circuits, with a C curve and 16 A rating. Match the circuit conductors and starting duty to this exact reference.

    Protection function
    Thermal-magnetic breaker
    Pole arrangement
    1P
    Rated current
    16 A

    Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.

    Pricing confirmed by quote

    Quote confirms reference and commercial terms; installation selection remains the installer’s responsibility.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    MW116 protects 1 poles against overloads and short circuits, with a C curve and 16 A rating. Match the circuit conductors and starting duty to this exact reference.

    Relevant applications

    • Selected commercial distribution or equipment circuits, matched to the documented supply and protection function.

    Why ReneWave may shortlist it

    • MW116 protects 1 poles against overloads and short circuits, with a C curve and 16 A rating. Match the circuit conductors and starting duty to this exact reference.

    System position

    AC protection: conceptual single-line view.

    Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.

    The closed device supplies L. Downstream branch protection remains separate. PE bypasses every switched pole. N also bypasses this phase-only breaker.

    MW116 protects 1 poles against overloads and short circuits, with a C curve and 16 A rating. Match the circuit conductors and starting duty to this exact reference. The closed device supplies L. Downstream branch protection remains separate. PE bypasses every switched pole. N also bypasses this phase-only breaker.AC circuit supplyLMW11616 A · CCommercial distributionSeparate branch protectionSelected site circuitsLoad / conductors selectedMW116 protects 1 poles against overloads and short circuits, with a C curve and 16 A rating. Match the circuit conductors and starting duty to this exact reference. The closed device supplies L. Downstream branch protection remains separate. PE bypasses every switched pole. N also bypasses this phase-only breaker.AC circuit supplyLMW11616 A · CCommercial distributionSeparate branch protectionSelected site circuitsLoad / conductors selectedMW116 protects 1 poles against overloads and short circuits, with a C curve and 16 A rating. Match the circuit conductors and starting duty to this exact reference. The closed device supplies L. Downstream branch protection remains separate. PE bypasses every switched pole. N also bypasses this phase-only breaker.AC circuit supplyLMW11616 A · CCommercial distributionSeparate branch protectionSelected site circuitsLoad / conductors selected
    Read the technical explanation

    Overload and short-circuit protection, without integrated residual-current protection. Select separate leakage protection where required.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    Device identity

    Hager reference

    MW116

    Manufacturer EAN

    3250614531163

    Protection function

    Thermal-magnetic breaker

    Pole arrangement

    1P

    Rated current

    16 A

    Rated operational voltage

    230–400 V AC

    Trip curve

    C

    Neutral

    Only the phase is switched and protected; neutral bypasses this one-pole device.

    Electrical ratings

    Icn · IEC 60898-1

    3 kA · 230 V AC · IEC 60898-1

    Ui

    500 V

    Uimp

    4 kV

    Frequency

    50–60 Hz

    IP

    IP20

    Mounting and connections

    Modules / width

    1 / 17.5 mm

    Dimensions H × W × D

    83 × 17.5 × 70 mm

    Terminal torque

    2.8 Nm

    03 · Selection points

    Four practical selection points.

    Choose by circuit function, conductors and documented electrical limits.

    1. 01

      Pole arrangement

      Only the phase is switched and protected; neutral bypasses this one-pole device.

    2. 02

      Current and protection function

      Curve C: match starting currents and conductor protection to the 16 A rating. Ambient temperature affects the available continuous current; use the Hager derating table.

    3. 03

      Voltage and fault capacity

      Compare prospective fault current with the listed capacity at its stated voltage and standard. Do not substitute Icn, Icu or Ics for one another.

    4. 04

      Mounting and connections

      DIN-rail mounting, 1 modules / 17.5 mm wide. Follow the manufacturer's terminals and installation instructions. Nominal terminal torque: 2.8 Nm.

    04 · Documentation

    Keep the exact reference traceable.

    Published documents for this exact reference support selection and handover.

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Separate equipment is selected for the installation; no automatic companions are added to your request.

    No automatic companion selection. Separate protection and accessories are chosen for the installation.