Dyness SBDU100 controller and standard STACK100 floor base shown as separate supplied components
    Supplied package · authenticated exact-controller photography with the official standard-base hardware. No S51100 battery module is included.
    DynessBest Value

    Dyness SBDU100 STACK100 High-Voltage Battery Controller & Floor Base

    Exact reference · SBDU100

    The protection, communication and high-voltage connection layer for a Dyness STACK100 cluster, supplied with one standard floor base.

    Product role
    Battery distribution / control unit

    The SBDU100 contains no cells and contributes no energy capacity.

    Operating range
    134.4–864 V

    The actual cluster voltage depends on the selected 3–15-module stack and inverter window.

    Continuous current
    100 A maximum

    The recommended complete-stack operating current is 50 A; conductors and protection must suit the commissioned design.

    Included package
    SBDU100 + standard floor base

    No S51100 battery module is included.

    Installation boundary
    IP20 · indoor

    Use a suitable indoor location with documented support, restraint, clearances and environmental conditions.

    Do not select this controller from voltage range or STACK100 branding alone. Confirm module count, inverter protocol, firmware, cluster voltage, current, standard-versus-expansion base, indoor installation and commissioning records.

    Pricing confirmed by quote

    The written quote confirms the exact reference, required accessories, compatibility, delivery and commercial terms.

    Availability confirmed in your written quote

    1

    01 · Product role

    What this product does in the system.

    The SBDU100 sits above three to fifteen separately ordered S51100 modules and provides the cluster high-voltage connection, integrated DC breaker, status indication and inverter communications. The supplied standard floor base is physical mounting and circuit-connection equipment for one cluster; it is not a battery module.

    Relevant applications

    • Indoor commercial high-voltage storage systems
    • Single STACK100 clusters using 3–15 S51100 modules
    • Multi-cluster projects using the documented expansion-base and communication architecture

    Why ReneWave may shortlist it

    • Provides the STACK100 cluster DC breaker, power controls and status indicators.
    • Communicates with a separately validated inverter through CAN or RS485.
    • Includes the standard floor base required for a single-cluster installation.

    Built-in capabilities

    Four functions, read before the headline specifications.

    Manages cluster connections

    Connects the STACK100 battery cluster to a compatible high-voltage inverter interface.

    Operating range: 134.4–864 V.

    Provides fault protection

    Includes the documented DC breaker, power controls and status indicators.

    The SBDU maximum continuous-current boundary is 100 A.

    Coordinates communications

    Provides CAN and RS485 inverter links with WiFi and app OTA support.

    Protocol, firmware, cable and pinout remain inverter-specific.

    Coordinates 3–15 modules

    One SBDU100 manages a documented S51100 module stack.

    Multi-cluster expansion requires separate expansion-base equipment and commissioning.

    System position

    Where this controller sits in a STACK100 storage system.

    The SBDU100 connects separate S51100 modules to a compatible high-voltage inverter. It contains no cells, performs no AC conversion and cannot supply loads by itself. Physical package: one standard STACK100 floor base is included. It supports a single cluster and is not an electrical-flow node.

    PV supplies protected site loads through the compatible inverter. The STACK100 cluster remains idle.

    PV and utility sources connect through a separately selected compatible inverter and protected AC distribution. Three to fifteen separate S51100 modules charge and discharge through the SBDU100 high-voltage controller and that inverter. The standard floor base is included physical equipment, not an electrical node. No direct PV-to-battery, controller-to-AC-load, standalone backup or grid-export path is shown. PV supplies protected site loads through the compatible inverter. The STACK100 cluster remains idle.PV arrayseparate equipmentCompatible high-voltage inverter / chargerprotocol + firmware confirmedProtected AC distributionproject protection separateProtected site loadsserved through inverterDyness SBDU100controller · standard base included3–15 separate S51100 modules15.36–76.8 kWh nominalUtility supplyconditional charging sourcePV and utility sources connect through a separately selected compatible inverter and protected AC distribution. Three to fifteen separate S51100 modules charge and discharge through the SBDU100 high-voltage controller and that inverter. The standard floor base is included physical equipment, not an electrical node. No direct PV-to-battery, controller-to-AC-load, standalone backup or grid-export path is shown. PV supplies protected site loads through the compatible inverter. The STACK100 cluster remains idle.PV arrayseparate equipmentCompatible high-voltage inverter / chargerprotocol + firmware confirmedProtected AC distributionproject protection separateProtected site loadsserved through inverterDyness SBDU100controller · standard base included3–15 separate S51100 modules15.36–76.8 kWh nominalUtility supplyconditional charging sourcePV and utility sources connect through a separately selected compatible inverter and protected AC distribution. Three to fifteen separate S51100 modules charge and discharge through the SBDU100 high-voltage controller and that inverter. The standard floor base is included physical equipment, not an electrical node. No direct PV-to-battery, controller-to-AC-load, standalone backup or grid-export path is shown. PV supplies protected site loads through the compatible inverter. The STACK100 cluster remains idle.PV arrayseparate equipmentCompatible HV inverter / chargerseparate conversion equipmentProtected AC distributionseparate protectionProtected site loadsAC loadsDyness SBDU100controller · no cells3–15 separate S51100 modulesbattery stackUtility supplyconditional source
    Read the technical explanation

    The protection, communication and high-voltage connection layer for a Dyness STACK100 cluster.

    The supplied package contains one SBDU100 battery distribution/control unit and one standard STACK100 floor base. It contains no battery cells or energy capacity. A working cluster requires three to fifteen separately ordered S51100 modules and a validated high-voltage inverter/charger.

    Base and expansion boundary

    The standard base supports one cluster. Multi-cluster expansion requires the documented expansion-base conversion, communication and commissioning architecture; it is not an arbitrary parallel connection.

    02 · Specifications

    Ratings, dimensions and practical consequence.

    SBDU100 controller

    Operating range

    134.4–864 V

    Maximum continuous current

    100 A

    Communication

    CAN / RS485 · WiFi / app OTA

    Integrated equipment

    DC breaker · power controls · status indicators

    Dimensions

    590 × 390 × 133 mm

    Weight

    15.3 kg

    Enclosure

    IP20 · indoor

    Included standard base

    Package

    1 × standard STACK100 floor base

    Dimensions

    590 × 390 × 100 mm

    Weight

    6.7 kg

    Boundary

    Single-cluster base; expansion uses the documented expansion-base arrangement

    Complete STACK100 dependency

    Separate modules required

    3–15 × S51100

    Nominal energy

    15.36–76.8 kWh

    Usable energy

    14.592–72.96 kWh

    Current

    50 A recommended · 100 A continuous · 125 A for 2 minutes at 25°C

    Cluster expansion

    Up to 12 clusters with documented expansion equipment and commissioning

    03 · Confirm before quotation

    Four checks before this reference is quoted.

    ReneWave confirms the electrical context, connected equipment, installation conditions and configuration path before the exact reference enters a written quote.

    1. 01

      Stack composition

      Confirm one SBDU100, 3–15 S51100 modules and the correct standard or documented expansion-base arrangement.

    2. 02

      Inverter and BMS communication

      Confirm exact inverter model, high-voltage window, supported Dyness protocol, firmware, cable and pinout.

    3. 03

      Current and cluster design

      Confirm 50 A recommended, 100 A continuous and 125 A two-minute limits, plus conductors, breaker and multi-cluster architecture.

    4. 04

      Installation and records

      Confirm IP20 indoor conditions, floor support, wall restraint, clearances, grounding, WiFi, serials and commissioning records.

    04 · Documents & warranty

    Keep the exact reference traceable.

    Documents shown here support selection and handover. The accepted order and exact manufacturer warranty document control.

    Manufacturer warranty reference

    10 years

    • The retained component warranty explicitly lists SBDU100 and Stack100 Base
    • Exact serial, communication state, installation and delivered warranty terms control
    Customer Care

    05 · Complete the system

    Accessories and adjacent equipment, in one request.

    Select relevant companions now. ReneWave still verifies quantities and compatibility before they appear in the written quote.

    Required interfaces and add-ons

    Compare products
    ReneWave markRENEWAVE

    Energy systems, held to standard.