CHINT is a broad electrical manufacturer. The product we currently list is much narrower: the DTSU666-H 100 A measurement package for its documented Huawei application. Our Premium label belongs to that selection, not every CHINT product.
Authenticated manufacturer example. The selected product reference determines appearance and ratings.
01 / Who they are
Electrical products since 1984.
CHINT began in 1984 as the Yueqing Qiujing Switch Factory, making low-voltage switching equipment. The group entered new energy in 2006 through its solar business, including cell and module manufacturing. Today its portfolio also covers distribution, metering and solar projects. This guide concerns the CHINT equipment actually listed by ReneWave, especially inverter-compatible metering. A CHINT meter is not an Astronergy panel, and a generic DTSU666 does not automatically have the firmware, measurement range or interface required by a Huawei system.
The manufacturer’s corporate origins are not the manufacturing country of every supplied device. Read the exact label and documents.
Business development and revenue
The annual series below covers listed Zhejiang CHINT Electrics, including its electrical and energy activities. It does not represent the much larger CHINT Group total. Revenue rose in 2024 before declining in 2025. Keeping the reporting entity consistent avoids attributing group-wide solar manufacturing revenue to the meter and protection products considered here.
Revenue trend · USD billion
Annual revenue · USD billion
Year
Revenue
2023
$8.09
2024
$8.97
2025
$8.23
Listed Zhejiang CHINT Electrics consolidated revenue. The wider CHINT Group has a different reporting boundary. Amounts shown in USD billion. EUR and CNY amounts are converted using Federal Reserve annual-average rates; rounding and exchange rates affect comparisons.
Business milestones
Low-voltage switching first
The Yueqing Qiujing Switch Factory starts the business. Electrical switching precedes solar cell and module production.
1984 history illustration · illustrative example, not a photograph of this milestone.
Cells and modules add solar manufacturing
CHINT Solar is established, expanding into photovoltaic cells and panels. This group branch is distinct from CHINT’s metering equipment.
2006 history illustration · illustrative example, not a photograph of this milestone.
An APAC innovation and operating base
The Singapore headquarters and innovation lab expand regional operations. Product compatibility still follows the particular meter and inverter documentation.
2021 history illustration · illustrative example, not a photograph of this milestone.
02 / Technology
Selected technology advances
Selected developments in the brand’s specialty, not a complete history or catalog.
Understand the differences between the relevant families. Broader manufacturer offerings and the products ReneWave lists are kept separate below.
DTSU666-H 100 A example; not every variant
01
DTSU666-H 100 A
Meter and current-transformer package
The listed package uses its documented 100 A / 40 mA CT arrangement. That ratio is not a direct 100 A power-switching rating. The 100 A / 40 mA current-transformer ratio scales the measured conductor current to the meter input. CT direction, phase order and RS485 configuration determine measurement accuracy and inverter response. This meter measures energy flow; it neither supplies power nor interrupts faults.
The exact meter, CTs and firmware/system support belong together.
A similarly named meter is not silently substituted.
02
Broader CHINT portfolio
Other electrical families
CHINT also makes protection and other electrical equipment. Those broader families are not represented by this one measurement product. Generic DTSU666 meters, Huawei’s DTSU666-H package and other CT-ratio variants need separate identity checks. Matching the case or RS485 terminal is insufficient: the supported protocol, ratio and inverter instructions must match. CHINT’s wider protection portfolio performs a different role from this catalog meter.
Catalog presence is kept distinct from the manufacturer’s full offer.
Only products listed in ReneWave’s catalog appear below.
Key terms
Short definitions for the names used in this guide.
CT / RS485
Current transformation and data communication are separate from power conversion or circuit protection.
A current rating alone does not establish function, fault protection or circuit suitability.
03 / What stands behind the brand
Premium
What supports this Premium selection.
Exact identity and a documented system interface.
Our positioning applies to the selected range. The documented differences above explain the choice.
The defined CT package
The retained manufacturer sheet identifies the measurement package used in the supported application.
System-specific instructions
The Huawei-issued quick guide distinguishes meter identity and system communication. This is pairing evidence, not a blanket CHINT endorsement.
Measurement supports energy control
The documented CT ratio and supported inverter protocol make the meter useful for system control. Correct phase matching and CT direction are essential; another CHINT meter with the same case is not automatically compatible.
Published characteristics are useful evidence, not a promise of trouble-free operation or fast local warranty handling. Newer models do not inherit decades of field history from the company’s age.
The exact reference, market and supplied terms govern coverage. A datasheet or compliance certificate is not itself a warranty.
Coverage depends on the supplied terms
A universal manufacturer warranty duration for the listed references was not verified. Product defects are assessed under the applicable supplied warranty; protection coordination, installation faults and misuse are separate matters.
Product cover and system performance
Manufacturer product cover concerns qualifying defects in the supplied equipment. It does not establish the complete installation’s performance, an energy-yield guarantee or a fixed local claim-response time.
Questions before you buy
The product identity is CHINT DTSU666-H, supplied for its documented Huawei system application. Brand and application are different facts.
No. The stated CT ratio describes measurement, not a contactor or breaker function.
Not on name alone. The suffix, CT ratio and supported interface must match.